概览

CR850数据采集器是小型的研究级精度的数据采集器,作为一体式套装的一部分,含有内置的键盘显示器。倾向支持只测量少数几个传感器的小型应用。每个CR850读取传感器的读数,再通过通讯外设传送数据;可兼容大多数传感器和通讯设备。多个CR850可以被设置成数据采集器网络;或者,众多CR850单元也可被逐个配置。CR850结实耐用,可在严酷的远程环境中独立工作。

优势与特点

  • Integrated keyboard and display screen let you program, manually initiate data transfers, and view data, all on site.
  • Ideal applications include wind profiling, weather stations, ETo/agriculture, air quality, soil moisture, water level/stage, aquaculture, vehicle testing, Time Domain Reflectometry, SCADA, and water quality
  • Simpler in design, the CR800 and CR850 are easier to program and wire.
  • Serial communications with serial sensors and devices supported via I/O port pairs
  • Contains custom ASIC chip that expands pulse count, control port, and serial communications capabilities
  • Supports PakBus, Modbus, SDI-12, and DNP3 protocols
  • Compatible with channel expansion peripherals allowing you to expand your system
  • Includes both an CS I/O port and an RS-232 port for connecting communication devices
  • Gas Discharge Tube (GDT) protected inputs
  • Battery-backed clock that ensures accurate time is maintained while data logger is disconnected from battery power
  • Program with LoggerNet, PC400, or Short Cut to fit your setup

图像

技术说明

CR850包含封装在塑料壳内的带一体式接线面板的测量控制模块、16键的键盘、以及可显示8行21字符数值显示(或64x128像素绘图)的LCD显示屏。支持自定义菜单,方便用户通过简单切换或选取列表,来初始化数据采集器程序的选项设置功能。一体式的键盘和显示器用于启动数据采集器工作程序,初始化数据传输,显示数据。

CR850使用外部的键盘显示器和供电电源,极低的功耗使得CR850只需要使用小容量的可充电电池和太阳能板组合供电,从而不需要交流电源。为了减小非精确测量的可能性,当主电源低于 9.6 V时,CR850会暂停工作。

内部的操作系统包括数据采集器编程所需的测量、处理、输出指令。编程语言为CRBasic,使用类BASIC语法。测量指令包括:电桥设置、电压输出、热电偶、脉冲/频率信号。处理指令包括:代数运算、统计及用于现场处理的超越函数。输出指令按时间段处理数据,或控制外部设备。

产品规格

-NOTE- Note: Additional specifications are listed in the CR800-Series Specifications Sheet.
Operating Temperature Range
  • -25° to +50°C (standard)
  • Non-condensing environment
Maximum Scan Rate 100 Hz
Analog Inputs 6 single-ended or 3 differential (individually configured)
Pulse Counters 2
Voltage Excitation Terminals 2 (VX1, VX2)
Communications Ports
  • CS I/O
  • RS-232
Switched 12 Volt 1 terminal
Digital I/O
  • Certain digital ports can be used to count switch closures.
  • 4 I/Os or 2 RS-232 COM
    I/O ports can be paired as transmit and receive for measuring smart serial sensors.
Input Limits ±5 V
Analog Voltage Accuracy ±(0.06% of reading + offset) at 0° to 40°C
ADC 13-bit
Power Requirements 9.6 to 16 Vdc
Real-Time Clock Accuracy ±3 min. per year (Correction via GPS optional.)
Internet Protocols FTP, HTTP, XML POP3, SMTP, Telnet, NTCIP, NTP
Communication Protocols PakBus, Modbus, DNP3, SDI-12, SDM
Idle Current Drain, Average 1 mA (@ 12 Vdc)
Active Current Drain, Average
  • 1 to 16 mA (1 Hz sample rate @ 12 Vdc without RS-232 communication)
  • 16 mA (100 Hz sample rate @ 12 Vdc without RS-232 communication)
  • 28 mA (100 Hz sample rate @ 12 Vdc with RS-232 communication)
Dimensions 24.1 x 10.4 x 5.1 cm (9.5 x 4.1 x 2 in.)
Weight 0.7 kg (1.5 lb)

兼容性

Please note: The following shows notable compatibility information. It is not a comprehensive list of all compatible products.

软件

Product Compatible Note
LoggerNet (Version 3.3 or higher)
PC200W (retired)
PC400 (Version 1.4 or higher)
PCONNECT (retired) (Version 3.3 or higher)
PCONNECTCE (retired) (Version 2.2 or higher)
RTDAQ
Short Cut
VISUALWEATHER (Version 2 or higher)

Additional Compatibility Information

Sensors

With several channel types, the CR850 is compatible with nearly every available sensor, including thermocouples, SDI-12 sensors, and 4 to 20 mA sensors. A custom ASIC chip expands its pulse count, control port, and serial communications capabilities. The CR850's I/O ports can be paired as transmit and receive, allowing serial communications with serial sensors and devices.

Measurement & Control Peripherals

The CR850 is compatible with all of our CDMs (requires an SC-CPI), SDMs, multiplexers, vibrating-wire interfaces, terminal input modules, and relays. 

Communications

The CR850 communicates with a PC via direct connect, NL201 Ethernet Interface, multidrop modems, short haul modems, phone modems (land line, digital cellular, and voice-synthesized), RF telemetry, and satellite transmitters (Argos and High Data Rate GOES).

Data can be viewed on its onboard keyboard display, CD100 Mountable Display with Keypad, user-supplied iOS or Android device (requires LoggerLink), CD295 DataView II Display, or a user-supplied PDA (PConnect or PConnectCE software required).

The SC115 is the only compatible external data storage device. The CR850 does not have a peripheral port and is therefore not compatible with the CFM100, NL115, or NL120.

Enclosures

The CR850 and its power supply can be housed in any of our standard enclosures. 

Power

Any 12 Vdc source can power the CR850 datalogger. Power supplies commonly used with the CR850 are the BPALK, PS100, and PS200. The BPALK provides eight non-rechargeable D-cell alkaline batteries with a 7.5 A h rating at 20°C.

Both the PS100 and PS200 consist of a sealed rechargeable 7 A h battery and a charging regulator. Their battery should be connected to a charging source (either a wall charger or solar panel). These two power supplies differ in their charging regulator. The PS100 has a standard regulator and the PS200 has a micro-controller-based smart regulator. The PS200's regulator provides two-step constant voltage charging and temperature compensation that optimize battery charging and increases the battery’s life.

Also available are the BP12 and BP24 battery packs, which provide nominal ratings of 12 and 24 A h, respectively. These batteries should be connected to a regulated charging source (e.g., a CH100 or CH200 connected to a unregulated solar panel or wall charger).

Software

CRBasic, the CR850's full programming language, supports simple or complex programming and many onboard data reduction processes.

视频与教程

下载

CR800 OS v.32.05 (4.38 MB) 06-01-2020

Execution of this download installs the CR800 Operating System and Compiler on your computer.  It also updates the CR800 support files for the CRBasic Editor.  

Note: This OS has crossed the 2 Meg CR800 size limit for remote download.  The OS must be downloaded to the 2 Meg CR800 via direct connect with the Device Configuration Utility.  All OS download methods are supported by the 4 Meg CR800.

Upgrading from versions prior to version 28 of the Operating System will reset the datalogger’s CPU drive.  This is due to a change in the format of the file system from FAT16 to FAT32.  In order for the datalogger to operate correctly, as part of the upgrade, the CPU drive is formatted to FAT32.  Any programs stored and running from the CPU drive will be lost.  It is not recommended to update the datalogger’s Operating System over a remote connection where program control regulates the communication equipment (turning it on or off, etc.).  In these cases, an on-site visit and a backup using DevConfig’s backup utility is necessary to update the datalogger’s Operating System.

Watch the Video Tutorial: Sending an OS to a Local Datalogger.

In all cases where the datalogger is being updated from an Operating System prior to 28, the use of DevConfig’s backup utility is recommended due to the CPU drive being formatted using the new FAT32 format.

查看修订历史

Device Configuration Utility v.2.29 (54 MB) 15-11-2023

A software utility used to download operating systems and set up Campbell Scientific hardware. Also will update PakBus Graph and the Network Planner if they have been installed previously by another Campbell Scientific software package.

Supported Operating Systems:

Windows 11 or 10 (Both 32 and 64 bit)

查看修订历史

常见问题解答

CR850: 146

展开全部收起全部

  1. The SC115 (2 GB) is the only device capable of extending the memory of the CR800 or CR850.
  2. Yes. EX and VX are synonymous and refer to voltage excitation.
  3. No, unless the internal lithium battery is below 2.7 Vdc. The lithium battery helps preserve the data, program, and clock setting when the 12 Vdc battery is removed.
  4. Yes. The CR800 and CR850 are compatible with exactly the same options as the CR1000 but with a lower channel count.

  5. Use the CURS100 device or a precision 100 ohm resistor to make 4 to 20 mA measurements.

案例研究

路易斯安那州: 天坑监测
In August 2012, RESPEC was contracted to provide field instrumentation and early-warning monitoring services at......阅读更多
南达科他州: 管式灌溉系统
The semiarid region just north of the Black Hills in western South Dakota has vast......阅读更多
北卡罗莱纳: 警报站升级
The Charlotte-Mecklenburg Flood Information and Notification System (FINS) consists of over 125 gaging stations spread......阅读更多
墨西哥: 机场自动气象站
Weather is, of course, a critical component of safe and efficient air travel. Pilots, navigators,......阅读更多
New Zealand: Coal Mine Water Quality Monitoring
High-grade coal has been mined on the West Coast of New Zealand since the 1870s.......阅读更多