该版本的CR800用于OEM,订购后该产品不带标签,或者带有Sullair标签。
该版本的CR800用于OEM,订购后该产品不带标签,或者带有Sullair标签。
CR800为较小尺寸的测量和控制数据采集器,可在严酷的远程环境中独立工作。每个CR800读取来自传感器的输入信号,再通过通讯外设传送数据。多个CR800可被设置成一个测量控制网络,或者每台CR800可被设置成独立工作。
CR800的功耗极低,只需可充电电池加上太阳能板的组合就可持续工作,不需要交流电源。当供电电压降至9.6 V以下时,CR800会暂停工作,减少不精确测量的可能性。
典型的野外CR800系统包括:
CR800兼容我们的测量控制设备,几乎每个可用的传感器,以及我们大多数的通讯设备;请参考兼容性标签以查找更多信息。
Current Drain |
|
A/D Bits | 13 |
Scan Rate | 100 Hz |
Analog Inputs | 6 single-ended (3 differential), individually configured |
Analog Voltage Range | ±5000 mV |
Analog Voltage Accuracy | ±(0.06% of reading + offset) at 0° to 40°C |
Measurement Resolution | 0.33 µV |
Switched Excitations | 2 voltage |
Pulse Counters | 2 |
Control/Digital Ports | 4 |
Memory |
|
Communication Ports | 1 RS-232, 1 CS I/O |
Protocols Supported | PakBus, Modbus, DNP3, FTP, HTTP, XML, POP3, SMTP, Telnet, NTCIP, NTP, SDI-12, SDM |
Dimensions | 24.1 x 10.4 x 5.1 cm (9.5 x 4.1 x 2 in.) |
Weight | 0.7 kg (1.5 lb) |
With several channel types, the CR800 is compatible with nearly every available sensor, including thermocouples, SDI-12 sensors, and 4 to 20 mA sensors. A custom ASIC chip expands its pulse count, control port, and serial communications capabilities. The CR800's I/O ports can be paired as transmit and receive, allowing serial communications with serial sensors and devices.
The CR800 is compatible with all of our contemporary SDMs, multiplexers, vibrating wire interfaces, terminal input modules, and relays.
The CR800 communicates with a PC via direct connect, NL100 Ethernet Interface, multidrop modems, phone modems (land line, digital cellular, and voice-synthesized), RF telemetry, and satellite transmitters (Argos, High Data Rate GOES, and Meteosat). Data can be viewed on the CR1000KD Keyboard Display, CD295 DataView II Display, Archer-PCon Field PC, or a user-supplied PDA (PConnect or PConnectCE software required).
The SC115 is the only compatible external data storage device. The CR800 does not have a peripheral port and is therefore not compatible with the CFM100, NL115, or NL120.
The CR800 and its power supply can be housed in an ENC12/14, ENC14/16, or ENC16/18 enclosure.
Any 12-Vdc source can power the CR800 datalogger; a PS100 or BPALK is typically used. The PS100 provides a 7-Ahr sealed rechargeable battery that should be connected to a charging source (either a wall charger or solar panel). The BPALK consists of eight non-rechargeable D-cell alkaline batteries with a 7.5-Ahr rating at 20°C.
Also available are the BP12 and BP24 battery packs, which provide nominal ratings of 12 and 24 Ahrs, respectively. These batteries should be connected to a regulated charging source (e.g., a CH100 connected to a unregulated solar panel or wall charger).
CRBasic, the CR800's full programming language, supports simple or complex programming and many onboard data reduction processes. Compatible software includes: