太阳辐射传感器 / LI200RX-L
停产的 ›
这个产品是无效的且被替换: CS320.
LI200RX-L Pyranometer with Fixed Calibration
Services Available
Repair No
Calibration Yes
Free Support No

概览

The LI200RX pyranometer measures both sun and sky solar radiation with a silicon photovoltaic detector mounted in a cosine-corrected head. The cable contains circuitry that standardizes sensor calibration, allowing complete sensors and cabling to be swapped out in the field without having to change the data logger programming. 

This pyranometer connects directly to Campbell Scientific data loggers and is ideal for agricultural and meteorological applications. The LI200RX is calibrated for natural light. Campbell Scientific does not recommend using the LI200RX under artificial light or plant canopy.

优势与特点

  • Compatible with most Campbell Scientific data loggers
  • Sensor and cable can be swapped out in the field with no changes to the data logger program
  • Ideal for solar, agricultural, and meteorological applications
  • Measures sun plus sky radiation

图像

LI200RX-L with cable
LI200RX-L with cable
LI200RX-L with cable
LI200RX-L with LI2003S leveling base (sold separately)
Close-up view of the LI200RX-L sensor head
LI200RX-L with a LI2003S leveling base, mounting bracket, and CM225 (all sold separately)
LI200RX-L with a LI2003S leveling base, mounting bracket, and CM225 (all sold separately)
LI200RX-L with a LI2003S leveling base, mounting bracket, and CM225 (all sold separately)

技术说明

The LI200RX pyranometer monitors sun plus sky radiation. It connects directly to Campbell Scientific data loggers and is used extensively in solar, agricultural, and meteorological applications. This pyranometer includes a completion circuit in its cable that standardizes calibration, allowing complete sensors and cabling to be interchanged without altering multiplier and offset values.

The LI200RX sensor head is calibrated against an Eppley Precision Spectral Pyranometer to accurately measure sun plus sky radiation. Campbell Scientific does not recommend using the LI200RX under vegetation or artificial lights because it is calibrated for the daylight spectrum (400 to 1100 nm).

产品规格

Light Spectrum Waveband 400 to 1100 nm
Calibration ±5% traceable to the U.S. National Institute of Standards Technology (NIST)
Sensitivity 0.2 kW m-2 mV-1
Linearity Maximum deviation of 1% up to 3000 W m-2
Absolute Error in Natural Daylight
  • ±5% (maximum)
  • ±3% (typical)
Shunt Resistor Adjustable, 40.2 to 90.2 Ω (factory set to give the above sensitivity)
Stability < ±2% change over a 1-year period
Response Time < 1 μs
Temperature Dependence 0.15% per °C (maximum)
Cosine Correction Cosine corrected up to 82° angle of incidence
Diameter 2.36 cm (0.93 in.)
Height 3.63 cm (1.43 in.)
Weight 84 g (2.96 oz)

兼容性

Please note: The following shows notable compatibility information. It is not a comprehensive list of all compatible products.

数据采集器

Product Compatible Note
21X (retired)
CR10 (retired)
CR10X (retired)
CR200X (retired)
CR206X (retired)
CR211X (retired)
CR216X (retired)
CR23X (retired)
CR295X (retired)
CR3000 (retired)
CR500 (retired)
CR5000 (retired)
CR510 (retired)
CR6
CR800 (retired)
CR850 (retired)
CR9000 (retired)

Additional Compatibility Information

Mounts

To ensure accurate measurements, the sensor should be leveled using an LI2003S leveling fixture, which incorporates a bubble level and three adjusting screws. The LI2003S leveling fixture mounts to a tripod or tower using the CM225 mount. Campbell Scientific recommends mounting the LI200RX-L away from all obstructions and reflective surfaces that might adversely affect the measurement.

Data Logger Considerations

The LI200RX-L requires one differential analog input channel per probe.