CH201 OS 3.0
更新: 29-03-2024

  1. Created a 0.9-volt differential between the turn off low voltage disconnect voltage set point and the required reconnect voltage. The battery voltage will need to recover 0.9 V above the low voltage disconnect value for 30 seconds before the device will re-enable the peripheral output voltage.