RTMC 实时监测控制软件

概览

RTMC 实时监测控制软件附带在我们的LoggerNet,LoggerNet Admin,LoggerNetData和RTDAQ 软件内。可图形化显示数据,设置输入位置和切换端口和标志。简单但功能强大的用户界面,RTMC 可用于如警报、滑块、图形切换、表格等多标签显示。如需更多显示,请参看RTMC Pro。

优势与特点

  • Real-time monitoring and control software bundled with LoggerNet, LoggerNet Admin, and RTDAQ software

图像

技术说明

RTMC Real-time Monitoring and Control Software is bundled with our LoggerNet, LoggerNet Admin, and RTDAQ software. It graphically displays data, sets input locations, and toggles ports and flags. A simple yet powerful user interface allows RTMC to use components such as alarms, sliders, graphs, toggles, tables, and gauges to design custom multi-tab displays.

RTMC's bitmap-based display system provides the tools used to tailor your displays. It can simultaneously display data from any number of data loggers in the network. RTMC can access statistical data reported by the server, including the current state of your data logger network and system-critical information used to trigger alarms. All of RTMC's functions are available when connected as a client to a server on a remote PC. RTMC also includes a sophisticated real-time mathematical compiler for performing real-time calculations. With its point-and-click interface, RTMC is a simple solution for generating real-time displays.

产品规格

Current Version 5.0
Operating System Windows 11 or 10 (Both 32- and 64-bit operating systems are supported.)
Purchased Separately No (Bundled with LoggerNet, LoggerNet Admin, and RTDAQ software)
Software Level Entry
Real-Time Updates Yes
Alarms Real-time, visual, audible

兼容性

Please note: The following shows notable compatibility information. It is not a comprehensive list of all compatible products.

数据采集器

Product Compatible Note
21X (retired)
CR10 (retired)
CR1000X
CR10X (retired) RTMC is compatible with the mixed array, PakBus, and TD data logger operating systems for the CR510, CR10X, and CR23X dataloggers.
CR200X (retired)
CR206X (retired)
CR211X (retired)
CR216X (retired)
CR23X (retired) RTMC is compatible with the mixed array, PakBus, and TD data logger operating systems for the CR510, CR10X, and CR23X dataloggers.
CR295X (retired)
CR300
CR3000 (retired)
CR310
CR350
CR500 (retired)
CR5000 (retired)
CR510 (retired) RTMC is compatible with the mixed array, PakBus, and TD data logger operating systems for the CR510, CR10X, and CR23X dataloggers.
CR6
CR800 (retired)
CR850 (retired)
CR9000 (retired)

Additional Compatibility Information

Computer

RTMC runs on Windows 10 and 11. RTMC runs on both 32-bit and 64-bit versions of these operating systems.

常见问题解答

RTMC: 23

展开全部收起全部

  1. A network may need to be loaded into LoggerNet from a backup file. If there was no backup, an identical network must be set up in the LoggerNet Setup for the RTMC project to run.

  2. Users can control the look of their projects to some extent through Edit | Preferences | Graphics Quality. The default option is High Quality, which uses anti-aliased fonts when rendering text. Lowering the graphic quality changes the text so that it is rendered in more of a block fashion.

  3. Access the Public table in the data logger to use SetPoint. By changing the station setup to retrieve the Public table, it should show up in RTMC as being able to read/write to.

  4. Yes, provided the serial sensor is connected to a port that is separate from the one used to connect to LoggerNet.

  5. The project needs to be designed in RTMC Pro using the development environment. The project can then be run within the development environment or by using RTMC Run-Time.

  6. Most controls in RTMC work with mathematical expressions for their fields. For example, if there is a table named one_hour on station stat with a field named temp_degc, an expression can be entered to convert this to degrees Fahrenheit as follows:

    1.8 * "stat.one_hour.temp_degc" + 32

  7. Yes. The “Getting Started with RTMC Tutorial” is available for download.

  8. Yes. In RTMC, there is a Value Forwarder component that can be used to read a value from one data logger and send it to another.

  9. Value forwarders can be used to keep all of the values synchronized. Use the switch to set the value in one data logger, and then use multiple value forwarders to read this value and forward it on to the other data loggers. The value forwarders can be set as hidden so that they don’t show up in runtime.

  10. RTMC can be used to create real-time time-series plots of many parameters.

案例研究

South Africa: Launch of an Innovative Science Facility with Sustainable Technology
The Department of Science and Innovation (DSI) and its partners, including the Department of Basic......阅读更多