03101 3-杯风速计包括在我们的03001风速风向传感器中。可根据应用单独采购风速计。03101可与Campbell Scientific的数据采集器连接,测量风速计的脉冲信号,并转换成相应的单位,例如 mph, m/s, knots。
03101 利用风杯转动测量风速。风杯的旋转产生与风速成正比的交流正弦波,数据采集器的脉冲通道测量交流正弦波的频率,并转换为风速单位(mph, m/s, knots)。Campbell Scientific版本的03101使用屏蔽式轴承,可降低风速计的监测限值。
Sensor | 3-cup anemometer |
Measurement Description | Wind speed |
Range | 0 to 50 m/s (112 mph) |
Gust Survival | 60 m/s (134 mph) |
Sensor | 12-cm diameter cup wheel assembly, 40-mm diameter hemispherical cups |
Accuracy | ±0.5 m/s (1.1 mph) |
Turning Factor | 75 cm (2.5 ft ) |
Distance Constant | 2.3 m (7.5 ft) 63% recovery |
Starting Threshold | 0.5 m/s (1.1 mph) |
Transducer | Stationary coil (1300 ohm nominal resistance) |
Output Frequency | 1 cycle per cup wheel revolution (0.75 m/s per Hz) |
Transducer Output | AC sine-wave signal induced by rotating magnet on cup wheel shaft 100 mV peak-to-peak at 60 rpm (6 V peak-to-peak at 3600 rpm) |
Operating Temperature Range | -50° to +50°C (assumes non-riming conditions) |
Cup Wheel Diameter | 12 cm (4.7 in.) |
Height | 23.4 cm (9.2 in.) |
Weight | 113 g (4 oz) |
The 03101 anemometer is supplied with a galvanized 10-in.-long x ¾-in. IPS threaded pipe, which mounts to a crossarm via a CM220 mount or 1049 Nu-Rail fitting. The 03101 can also be mounted to the top of a CM106B or a stainless-steel tripod via the CM216.
An ideal application for the Wind Sentry is wind profile studies. For this application, the LLAC4 4-channel Low Level AC Conversion Module can be used to increase the number of anemometers measured by one data logger. The LLAC4 allows data logger control ports to read the anemometer’s ac signals instead of using pulse channels. Data loggers compatible with the LLAC4 are the CR200(X)-series (ac signal ≤1 kHz only), CR800, CR850, CR1000, CR3000, and CR5000.
The 03101 uses one pulse count channel on the data logger.
The 03101 is read by the PulseCount Instruction in CRBasic and by Instruction 3 (Pulse Count) in Edlog. Wind speed measurements can be taken and processed with any of the data loggers.
03101-L: 6
展开全部收起全部
Very low voltage outputs from the sensor could be the result of a bad coil or an internal magnet that was mounted incorrectly. Refer to the “Troubleshooting” section of the instruction manual for more information. If it is necessary to return the sensor to Campbell Scientific for repair, request a return material authorization (RMA) number by following the steps listed on our Repair and Calibration page.
No. But using a LLAC4 will convert the ac signal for up to four 03101-L sensors (and other ac output anemometers) to individual 0 to 5 Vdc TTL level square wave outputs. For more information, see the LLAC4 specification information.
The pulse output can’t be converted easily to a 4 to 20 mA output without additional equipment. For a wind monitor designed to generate a 4 to 20 mA output, refer to the R. M. Young website.
The cup assembly can be replaced with pn 4609, Replacement Wind Speed Cup Assembly for 03001 or 03101.
Follow these steps:
No. Installing the anemometer in a tilted position will cause damage to the bearings and the shaft, and the bearings will be infiltrated with water and dust.