MetSens300 多参数天气传感器
Measures 3 Common Meteorological Parameters
IEC 61724-1 Compliant
气象 应用支持 水资源 应用支持 能源 应用支持 湍流通量 应用支持 基础结构/工业设施 应用支持 土壤 应用支持

概览

The MetSens300 compact weather sensor measures air temperature, relative humidity, and barometric pressure in a single, combined instrument mounted inside three double-louvered, naturally aspirated radiation shields with no moving parts. Temperature, relative humidity, barometric pressure, absolute humidity, air density, and wet bulb temperature data are provided. The MetSens300 is compatible and easily integrated with the MeteoPV Solar Resource Platform and any Campbell Scientific data logger using SDI-12, RS-485, ModbusRS-485, or NMEA RS-232.

优势与特点

  • Quality measurements
  • Fast and simple to install
  • Compact, integrated design
  • Lightweight and robust

图像

Cable for the MetSens300

产品规格

Measurements Made Air temperature, barometric pressure, and relative humidity.
Sampling Rate 1 Hz
Digital Communication Modes Serial RS-232, RS-485, SDI-12, NMEA, Modbus, ASCII
IP Rating 66
Compliance
  • CE, RoHS
  • Where applicable, all individual parameters meet or exceed specifications of IEC 61724-1 (2017, 2021).
Operating Temperature Range -40° to +70°C
Operating Voltage 5 to 30 Vdc
Typical Current Drain @ 12 Vdc
  • 25 mA (continuous high mode)
  • 0.7 mA (eco-power mode; 1 hour polled)
Weight 0.5 kg (1.1 lb)

Air Temperature Measurement

Measurement Range -40° to +70°C
Resolution 0.1°C
Accuracy ±0.3°C (@ 20°C)

Relative Humidity Measurement

Measurement Range 0 to 100%
Resolution 0.1
Accuracy ±2% @ 20°C (10 to 90% RH)

Barometric Pressure Measurement

Measurement Range 300 to 1100 hPa
Resolution 0.1 hPa
Accuracy ±0.5 hPa (@ 25°C)

下载

MetSens300 Example Programs v.1 (4 KB) 25-09-2019

Three CR1000X data logger programs that read the MetSens300 measurements and sensor status. An example program is included for each output option (RS-232, Modbus, SDI-12).

常见问题解答

MetSens300: 1

    • MetSens has a compass module that outputs at 1 Hz real time without affecting any other measurements, which allows the correction of wind direction if the station is installed on moving ice.
    • MetSens has a two-year service life, which is especially helped by the use of a double-louvered radiation shield to reduce the flow of contaminants getting to the temperature/humidity probe.
    • MetSens has an option for GPS.
    • MetSens has a wind speed resolution of 0.01 m/s, whereas most all-weather sensors have a resolution of 0.1 m/s.
    • MetSens has a dew point accuracy of ± 0.3°C, whereas most all-weather sensors have an accuracy of > ±0.7°C.
    • MetSens temperature resolution is for the full-range temperature at 0.1°C, whereas other all-weather sensors change to 0.2° at the extremes.
    • MetSens offers users the option to use any industry-standard tipping bucket rain gage (MetSens550).
    • MetSens provides RS-232, RS-485, Modbus, and SDI-12 from all models.
    • MetSens uses Intelligent Signal Processing (ISP) and Adaptive Gain Control (AGC), which have been proven worldwide to provide good quality data.
    • MetSens does not indicate a drop in wind speed if the temperature drops or if rain occurs, whereas this is fairly common in other all-weather sensors.

文章和新闻发布

列在

Common Accessory for the following products: