CWB100E为Campbell Scientific无线传感器网络中的主电台,可从多达50个无线传感器问询并存储数据,然后将数据传送到数据采集器上。问询的时刻和无线传感器的数目是可设置的。CWB100E采用跳频的射频电台,适合长距离通讯及干扰更少。868-MHz频段用于欧洲和世界上其它一些地区。
CWB100E基站用于Campbell Scientific的无线传感器网络,它含有一个内部的868-MHz射频电台,可从网络内的无线传感器收集数据。CWB100E的无线频段通常用于欧洲。数据采集器连接到CWB100E,来处理和存储无线传感器的数据。
在那些使用有线传感器会产生一些问题的站点,继续使用有线方式会有一些问题。首先,为了保护线缆,需要穿管、挖沟,既费时又费力,有些时候甚至没有可能性。当地的防火规范可能会禁止建筑内部使用某些类型的线缆。在某些应用中,测量需要通过较长距离实现,而较长的线缆可能会降低测量质量,或者成本太高。还有些时候,增加测量的数目非常重要,而数据采集器又没有留有足够的通道用于接入额外的传感器线缆。
Operating Temperature Range | -25° to +50°C |
Operating Relative Humidity | 0 to 100% (non-condensing) |
Power Source | Data logger |
Voltage | 4.5 to 22 Vdc |
Standby Typical Current Drain | < 1 mA (@ 12 Vdc) |
Receive Typical Current Drain | 10 mA (@ 12 Vdc) |
Transmit Typical Current Drain | 20 mA (@ 12 Vdc) |
Communication | Serial protocol or USB |
Terminal Block Connector | Bi-directional serial data logger connection |
USB Port | Computer connection for configuration |
Antenna Type | RPSMA antenna connection |
Memory Capacity | Can store data table for up to 50 wireless sensors. |
Dimensions | 10.8 x 4.4 x 4.4 cm (4.25 x 1.75 x 1.75 in.) including mounting bracket |
Weight | 140 g (5 oz) |
Internal 25 mW FHSS Radio |
|
Frequency | 868 MHz |
Where Used | Europe |
FHSS Channel | 16 |
Transmitter Power Output | 25 mW (+14 dBm) |
Receiver Sensitivity | -110 dBm (0.1% frame error rate) |
Standby Typical Current Drain | 3 μA |
Receive Typical Current Drain | 18 mA (full run) |
Transmit Typical Current Drain | 45 mA |
Average Operating Current | 15 μA (with 1-second access time) |
Quality of Service Management | RSSI |
Additional Features | GFSK modulation, data interleaving, forward error correction, data scrambling, RSSI reporting |
Please note: The following shows notable compatibility information. It is not a comprehensive list of all compatible products.
Product | Compatible | Note |
---|---|---|
CR200X (retired) | ||
CR206X (retired) | ||
CR211X (retired) | ||
CR216X (retired) | ||
CR295X (retired) | ||
CR3000 (retired) | Must have data logger OS version 21 or higher. | |
CR6 | The CR6 datalogger must have data logger OS version 4.0 or higher. | |
CR800 (retired) | Must have data logger OS version 21 or higher. | |
CR850 (retired) | Must have data logger OS version 21 or higher. |
The data logger is programmed to interface with the CWB100E and determine a polling interval. The sensors make their measurements as they are polled. The base station polls all sensors and stores the collected data early enough that it can transfer the data as soon as the data logger requests it. This minimizes the amount of time the data logger needs to wait for a response from the network through the CWB100E base station.
At the start of each polling interval, the data logger polls the base station, and sensor values are transferred to the data logger for storage. This method of data transfer from the sensors to the data logger provides the fastest and lowest power method available.
Windows USB drivers for the CWB100 are installed via the Device Configuration Utililty. In the Device Configuration Utility, click on the link "install the device driver for the CWB100" in the main body of text for the CWB100.
Note: Driver must be installed before connecting the CWB100 to your computer.