RETIRED ›
This product is not available for new orders.
ST350 应变传感器
Services Available

概览

ST350 应变传感器用于评估建筑的活载压力,例如桥梁、建筑物、起重机或大型的游乐园设施的活载压力。通过定制可与我们的数据采集器直接相连,对于结构/岩土数据监测系统是一款非常理想的仪器。

优势与特点

  • Improved signal-to-noise ratio means higher-resolution measurements
  • Rugged enough for harsh environments
  • Pay for themselves with just a few uses
  • Compatible with most Campbell Scientific data loggers
  • Quick installation with minimal preparation
  • Efficient, reliable, and highly accurate

图像

技术说明

The ST350 uses Wheatstone bridge circuitry, which converts small changes in resistance to an output voltage that our data loggers can measure. Its construction avoids the tedious and time-consuming effort required when using foil strain gages. This allows the ST350 to be installed within minutes on steel, concrete, timber, and FRP members.

 

产品规格

Accuracy ±2% (individually calibrated to NIST standards)
Force Required for 1000 με ~76 N (17 lb)
Strain Range ±2000 με
Sensitivity ~500 με/mV/V
Circuit Full Wheatstone bridge with 4 active 350 Ω foil gages, 4-wire hookup
Cable BDI RC-187 (22 gage, two individually shielded pairs with drain; 15 ft length standard)
Material Aluminum
Dimensions 11.1 x 3.2 x 1.3 cm (4.375 x 1.25 x 0.5 in.)
Weight 85 g (3 oz)

兼容性

Please note: The following shows notable compatibility information. It is not a comprehensive list of all compatible products.

数据采集器

Product Compatible Note
21X (retired)
CR10 (retired)
CR10X (retired)
CR200 (retired)
CR205 (retired)
CR206 (retired)
CR210 (retired)
CR211 (retired)
CR215 (retired)
CR216 (retired)
CR23X (retired)
CR295 (retired)
CR3000 (retired)
CR500 (retired)
CR5000 (retired)
CR510 (retired)
CR800 (retired)
CR850 (retired)
CR9000 (retired)

Additional Compatibility Information

Mounting

The ST350 is affixed to steel, pre-stressed concrete, or wood via two threaded mounting tabs and a tab jig. Alternatively, two C-clamps may be used to mount the sensor to steel. Attachment to reinforced concrete typically requires two threaded mounting tabs, a transducer extension, and an extension jig.


常见问题解答

ST350: 4

展开全部收起全部

  1. Customers have reported using the ST350 in applications similar to this.

  2. Generally, the recommended maximum strain for the ST350 is approximately 1,000 microstrain because of real-world installation conditions. The gage itself is capable of a higher microstrain measurement. For information regarding microstrain limits, refer to the “Instructions for Using ST350 Strain Transducer Extensions on Reinforced Concrete Structures” section in Appendix A of the “ST350 Strain Transducer Instruction Manual.”

  3. Use the full-bridge instruction, BrFull(). An example program for the CR1000 can be found in the “Datalogger Programming” section of the “ST350 Strain Transducer Instruction Manual.”

  4. The ST350 is designed as a full-bridge strain transducer with four active elements that can be directly connected to a data logger (or a multiplexer connected to a data logger) without adding a completion module such as the 4WFBS350 or 4WFBS120.