专为海洋、海岸应用设计,重量轻,耐用,可测量风速风向。制造厂商为 R. M. Young,通过线缆连接Campbell Scientific的数据采集器。
05106 采用耐用的抗紫外线的热塑塑料,不锈钢和阳极电镀铝材质。耐热塑料可抗击海洋空气环境的侵蚀,抵抗大气污染。精密级别的不锈钢滚珠轴承用于旋桨轴承和立式轴承。
专为海岸和海洋应用设计,经久耐用,05106采用防水的轴承润滑剂以及密封高性能的尾线代替了标准接线盒。
05106 用四叶螺旋状叶轮测量风速。叶轮旋转产生与风速成正比的频率的交流正弦波。传感器线圈中感应的交流信号由安装在传动轴六极磁铁生成。线圈固定在不能旋转的主安装组件的中部,省去了滑环和电刷。
连接在内部电位计上的机身状的传感器被用来感应风向。数据采集器将已知的精确的激发电压传向电位计元件。输出的模拟电压信号与方位角成正比。
Operating Temperature Range | -50° to +50°C (assuming non-riming conditions) |
Mounting Pipe Description |
|
Propeller Diameter | 18 cm (7.1 in.) |
Overall Height | 37 cm (14.6 in.) |
Overall Length | 55 cm (21.7 in.) |
Main Housing Diameter | 5 cm (2.0 in.) |
Weight | 1.5 kg (3.2 lb) |
Wind Speed |
|
Range | 0 to 100 m/s (0 to 224 mph) |
Accuracy | ±0.3 m/s (0.6 mph) or 1% of reading |
Starting Threshold | 1.1 m/s (2.4 mph) |
Distance Constant | 2.7 m (8.9 ft) 63% recovery |
Output |
ac voltage (three pulses per revolution) 90 Hz (1800 rpm) = 8.8 m/s (19.7 mph) |
Resolution | (0.0980 m s-1)/(scan rate in seconds) or (0.2192 mph)/(scan rate seconds) |
Wind Direction |
|
Mechanical Range | 0 to 360° |
Electrical Range | 355° (5° open) |
Accuracy | ±3° |
Starting Threshold | 1.1 m/s (2.4 mph) at 10° displacement |
Distance Constant | 1.3 m (4.3 ft) 50% recovery |
Damping Ratio | 0.3 |
Damped Natural Wavelength | 7.4 m (24.3 ft) |
Undamped Natural Wavelength | 7.2 m (23.6 ft) |
Output |
|
Voltage | Power switched excitation voltage supplied by data logger |
Please note: The following shows notable compatibility information. It is not a comprehensive list of all compatible products.
Product | Compatible | Note |
---|---|---|
CR500 (retired) | Measurements are typically processed for output with the Wind Vector instruction, which is not present in the CR500. | |
CR9000 (retired) | Measurements are typically processed for output with the Wind Vector instruction, which is not present in the CR9000. |
The 05106-L is compatible with most of our data loggers.
05106-L: 3
展开全部收起全部
This depends on what is broken. Typically, Campbell Scientific can repair the unit, and the user does not have to purchase a new one.
The information included on a calibration sheet differs with each sensor. For some sensors, the sheet contains coefficients necessary to program a data logger. For other sensors, the calibration sheet is a pass/fail report.