SC-CPI Datalogger-to-CPI Interface
Data Logger to CDM Bridge
Synchronized high-speed measurements
气象 应用支持 水资源 应用支持 能源 应用支持 湍流通量 应用支持 基础结构/工业设施 应用支持 土壤 应用支持

概览

The SC-CPI is an interface between the serial port of later-model Campbell Scientific dataloggers (CR800/850, CR1000, and CR3000) and our new Campbell distributed modules (CDMs). The CDMs use the new CAN peripheral interface (CPI), and the SC-CPI allows the dataloggers listed above to connect to the CDM's CPI port. 

An SC-CPI is required to connect Campbell Distributed Modules (CDMs), such as the CDM-A116, to a CR800, CR850, CR1000, or CR3000 datalogger. The SC-CPI is not required for, or supported by, dataloggers with a native CPI interface. Campbell Scientific strongly recommends that CDMs be connected to dataloggers with a native CPI interface, such as the CR6.

优势与特点

  • Enables a CR800, CR850 CR1000, or CR3000 to be part of a CPI/CDM network
  • Provides detailed CPI communication diagnostics
  • Supports monitoring of the serial or CPI load
  • Indicates if CPI frame errors occur
  • Provides information about each CPI module that it detects in its network

图像

SC-CPI shown with connector and 29526 cable attached (a Ships With item)
SC-CPI shown with connector and 29526 cable attached (a Ships With item)
SC-CPI shown with connector and 29526 cable attached (a Ships With item)

产品规格

Temperature Range
  • -25° to +50°C (standard)
  • -55° to +85°C (extended)
Current Drain 50 mA (active)
Dimensions 15.94 x 7.49 x 3.18 cm (6.28 x 2.95 x 1.25 in.) including ground lug
Weight 0.188 kg (0.415 lb)

Connectors

CPI RJ45
Serial Connect to Data Logger Screw terminal
Computer Configuration via Device Configuration Utility USB

兼容性

Please note: The following shows notable compatibility information. It is not a comprehensive list of all compatible products.

数据采集器

Product Compatible Note
CR200X (retired)
CR206X (retired)
CR211X (retired)
CR216X (retired)
CR295X (retired)
CR3000 (retired)
CR800 (retired)
CR850 (retired)

Additional Compatibility Information

Data Logger Considerations

A 5-conductor cable connects the data logger to the SC-CPI, and an Ethernet cable connects the SC-CPI to the CDM.

The data logger operating system must be version OS 26.


常见问题解答

SC-CPI: 2

  1. To communicate with CDM devices using the CPI protocol, the CR3000, CR1000, CR850, and CR800 dataloggers require an SC-CPI device. Only one SC-CPI device per data logger is required. It is expected that the design of future Campbell Scientific data logger products will work with CPI-based modules directly.

  2. The communications protocol used by CDM devices is the CAN Peripheral Interface (CPI), which includes methods that are proprietary to Campbell Scientific.

列在

Common Accessory for the following products: