SC32B 光电隔离接口通常用于连接数据采集器的CS I/O 端口到 PC的RS-232端口上。这种接口可将电脑的 RS-232 端口的电压水平转换到数据采集器的CMOS水平,也可将数据采集器和电脑的电气系统隔离,从而防止接地回路,正常的静电放电和噪音。
The SC32B, or another interface, is required for direct communications between a PC and a CR510, CR10X, or CR7 datalogger. For our CR800, CR850, CR1000, and CR1000X dataloggers, the SC32B is often used to provide optical isolation between the data logger and PC. Although the on-board RS-232 port of the CR3000, CR5000, or CR9000X dataloggers is isolated, the SC32B can be interfaced with their CS I/O port when a second RS-232 port is required in the application.
The SC32B is shipped with an SC12 (2 ft) cable for attachment to the data logger and a 10873 (6 ft) cable for attachment to the PC. Alternatively, an SC12R-6 (6 ft) cable (purchased separately) can be used instead of the standard SC12 when a longer cable is needed.
The SC32B can support RS-232 cable lengths of up to 50 feet; longer cable lengths are not recommended. The longer cable should be on the data logger side of the interface (CMOS logic levels) as opposed to the RS-232 side, which is typically more sensitive to drops in signal voltage levels.
Baud Rates Supported | Up to 115 kbps |
Power | Drawn from the serial ports of the PC and data logger |
Typical Current Drain |
|
Connections | 9-pin RS-232 socket (female) port configured as DCE; 9-pin pin (male) port |
Operating Temperature Range | -25° to +50°C |
Dimensions | 4.1 x 2.3 x 7.6 cm (1.6 x 0.9 x 3.0 in.) |
Weight | 45.4 g (1.6 oz) |
Please note: The following shows notable compatibility information. It is not a comprehensive list of all compatible products.
Product | Compatible | Note |
---|---|---|
CR9000 (retired) | The CR9000 requires a CR9080 PAM module. |
The SC325B is compatible with data loggers that have a CS I/O port.
SC32B: 13
展开全部收起全部
Yes. It ships with both the SC12 and 10873 serial cables. Usually, the SC12 is connected to the data logger, and the 10873 is connected to the computer.
Non-isolated interfaces (that is, connection to the RS-232 port with a standard serial cable connection) can cause ground offset errors in analog measurements using a system connected to a PC and powered by an ac source. The SC32B provides isolation that may be important when recording low-level, single-ended voltage measurements.
There are several differences:
For comparisons, see the SC32A product page and the SC32B product page.
The SC929 has been functionally replaced by the SC32B. While the SC929 is still available, the SC32B has increased capability at a reduced cost. See the table for a comparison:
|
SC929 |
SC32B |
Optically Isolated |
No |
Yes |
Maximum Baud |
9600 |
115200 |
Current Draw |
8 mA |
Active < 200 µA |
Cables are an additional comparison point for these two products:
No, because it would not work. The SC32B is used to do the following:
This is not necessarily an error associated with the SC32B. The message means that an attempt to check or set the clock on a mixed-array data logger (CR10, CR21X, CR7X, CR10X, CR510, and CR23X) failed. There could be several reasons for this error.
The combination of the USB to serial (17394) and the SC32B is basically the same as the SC-USB. Both options enable communication between a computer and a data logger with a CS I/O port.