LI200X使用硅光电检测器测量全太阳和天空辐射。它直接地连接到我们的数据采集器,广泛用于太阳、农业和气象等应用。
LI200X 使用固定在余弦校正过的头部的硅光电检测器来测量太阳辐射。校准参考是 Eppley精密光谱太阳辐射表(PSP)。LI200X 精确测量400 到 1100 nm波段内的全太阳和天空辐射。校准到这个波段的传感器不应当用在冠层下或人工光源中。,传感器的线缆上配有并联电阻,将微安信号转换成毫伏信号,这样LI190SB就可以直接由坎贝尔数据采集器来测量。
LI200X的线缆中包含环氧树脂封装的完成电路,标准化传感器的校准系数,使得无需改变乘数和偏移量值就可以互换传感器。
LI-200X传感器的标准输出是0.005 mV 每 W m-2,在全太阳辐射(1000 W m-2)下可提供5 mV的信号。我们所有的数据采集器,除了CR200(X)系列,都能测量该输出。
Light Spectrum Waveband | 400 to 1100 nm |
Accuracy | Absolute error in natural daylight is ±5% maximum (±3% typical) |
Sensitivity | 0.2 kW m-2 mV-1 |
Linearity | Maximum deviation of 1% up to 3000 W m-2 |
Shunt Resistor | Adjustable, 40.2 to 90.2 ohm (factory set to the above sensitivity) |
Stability | < ±2% change over a 1 year period |
Response Time | 10 μs |
Temperature Dependence | 0.15% per °C (maximum) |
Cosine Correction | Cosine corrected up to 80° angle of incidence |
操作温度范围 |
-40° to +65°C The overmolding that protects the completion circuit in the cable may crack if the temperature drops below -40°C. |
Relative Humidity Range | 0 to 100% |
Detector | High stability silicon photovoltaic detector (blue enhanced) |
Sensor Housing | Weatherproof anodized aluminum case with acrylic diffuser and stainless-steel hardware |
Diameter | 2.38 cm (0.94 in.) |
Height | 2.54 cm (1.00 in.) |
Weight | 28 g (1 oz) |
Please note: The following shows notable compatibility information. It is not a comprehensive list of all compatible products.
Product | Compatible | Note |
---|---|---|
21X (retired) | ||
CR10 (retired) | ||
CR10X (retired) | ||
CR200X (retired) | ||
CR206X (retired) | ||
CR211X (retired) | ||
CR216X (retired) | ||
CR23X (retired) | ||
CR295X (retired) | ||
CR3000 (retired) | ||
CR500 (retired) | ||
CR5000 (retired) | ||
CR510 (retired) | ||
CR6 | ||
CR800 (retired) | ||
CR850 (retired) | ||
CR9000 (retired) |
To ensure accurate measurements, the sensor should be leveled using a LI2003S leveling fixture, which incorporates a bubble level and three adjusting screws. The LI2003S leveling fixture mounts to a tripod or tower using the CM225 mount. For most applications, Campbell Scientific recommends attaching the CM225 to a CM202, CM204, or CM206 crossarm. The CM225 can also be attached to a tripod or tower mast.
One differential analog input channel per probe is required.
LI200X-L: 2
The LI190SB-L measures photosynthetically active radiation (PAR), a spectral range of solar radiation from 400 to 700 nm. This is the energy that plants use during photosynthesis. Measurements with the LI190SB-L are reported as photosynthetic photon flux density (PPFD).
The LI200X-L measures total solar radiation from 400 to 1100 nm. Measurements are usually reported in units of W/m2.
The information included on a calibration sheet differs with each sensor. For some sensors, the sheet contains coefficients necessary to program a data logger. For other sensors, the calibration sheet is a pass/fail report.