Services Available | |
---|---|
Repair | No |
Calibration | No |
Free Support | No |
PCONNECTCE/U 升级选项适用于先前已购买PConnectCE软件的客户。
PDA-to-RS232 线缆(在版本2.0中可用)包含在该升级选项中,其所带的接头允许订购1.X 升级到 2.X升级包的用户,拥有包含在完整PconnectCE2.X 软件包(非升级版)内的所有项目。
PConnectCE/U 项目升级PConnectCE 1.x 到版本2.33。
该升级项目不包含PDA-to-CS I/O 接头;不过,此升级选项中包含PDA-to-RS232接头(在2.0版本中包含)。包含接头允许订购升级1.X 到 2.X的用户,拥有包含在完整PconnectCE(非升级)2.X 软件包的所有项目。
Please note: The following shows notable compatibility information. It is not a comprehensive list of all compatible products.
Product | Compatible | Note |
---|---|---|
21X (retired) | ||
CR10 (retired) | ||
CR10X (retired) | For the CR510, CR10X, and CR23X, support for both the mixed-array and PakBus® data logger operating systems is provided in PConnectCE version 2.0 or higher; prior versions only supported the mixed-array OS. | |
CR200X (retired) | The CR200X-series and CR1000 dataloggers require PConnectCE version 2.0 or higher. | |
CR206X (retired) | The CR200X-series and CR1000 dataloggers require PConnectCE version 2.0 or higher. | |
CR211X (retired) | The CR200X-series and CR1000 dataloggers require PConnectCE version 2.0 or higher. | |
CR216X (retired) | The CR200X-series and CR1000 dataloggers require PConnectCE version 2.0 or higher. | |
CR23X (retired) | For the CR510, CR10X, and CR23X, support for both the mixed-array and PakBus® data logger operating systems is provided in PConnectCE version 2.0 or higher; prior versions only supported the mixed-array OS. | |
CR295X (retired) | The CR200X-series and CR1000 dataloggers require PConnectCE version 2.0 or higher. | |
CR3000 (retired) | The CR3000 requires PConnectCE version 2.1 or higher. | |
CR500 (retired) | ||
CR5000 (retired) | ||
CR510 (retired) | For the CR510, CR10X, and CR23X, support for both the mixed-array and PakBus® data logger operating systems is provided in PConnectCE version 2.0 or higher; prior versions only supported the mixed-array OS. | |
CR800 (retired) | The CR800 and CR850 require PConnectCE version 2.2 or higher. | |
CR850 (retired) | The CR800 and CR850 require PConnectCE version 2.2 or higher. | |
CR9000 (retired) |
--OR--
PDA-to-serial cable or cradle (one end of the cable/cradle must terminate in a 9-pin serial connector) is required. The cable/cradle connects to the PDA-to-CS I/O connector or PDA-to-RS232 cable via the 9-pin serial connector. This cable/cradle may be included with the PDA, or it may need to be purchased as a separate accessory from the PDA manufacturer or a third party supplier.
Third-party Bluetooth serial adapter is required. The interface and/or cables that are used to connect the adapter to the data logger will vary, depending upon whether the device acts like a DTE (computer) device or DCE (PDA) device. In some instances, this is evident by the pin-out of the adapter, but not always. A general rule is if the adapter has a 9-pin female connector, then the adapter is connected to the data logger using the PDA-to-CS I/O connector for the CS I/O port or the PDA-to-RS232 cable for the RS-232 port. If the adapter has a 9-pin male connector, then the adapter is connected to the data logger using an SC32B for the CS I/O port or it can be connected directly to the RS-232 port.