SC105 DCE 同步接口
Communication Support
气象 应用支持 水资源 应用支持 能源 应用支持 湍流通量 应用支持 基础结构/工业设施 应用支持 土壤 应用支持

概览

SC105 支持Campbell Scientific 的数据采集器和RS-232 DCE 设备之间的通讯,使用SC105的普通的DCE设备包括我们的 RavenXT 系列数字蜂窝调制解调器,第三方电台,第三方调制解调器。SC105 兼容所有的带有CS I/O接口的数据采集器。

优势与特点

  • Supports communication between a data logger and an RS-232 DCE device
  • Communicates at baud rates up to 115.2 kbps
  • Provides internal buffering capability to ensure no data is lost during transmission
  • Data logger can operate at a different baud rate than the DCE device
  • No power source needed—powered by the datalogger and computer
  • Compatible with most Campbell Scientific data loggers
  • Helps protect components from electrical damage
  • Ships with cables needed for most uses

图像

技术说明

The SC105 provides internal buffering that temporarily stores data. This buffering allows the data logger and DCE device to operate at different baud rates by storing the data received from the faster device until the slower device is ready to receive it. Internal buffering also ensures that no data is lost during transmission.

产品规格

Baud Rates Supported 1200, 9600, 19200, 38400, 57600, 115200 bps
RS-232 Parity Supported Even, odd, none
RS-232 Data Bits Supported 7, 8
CS I/O Port Modes CSDC, SDC, ME, Addressed Print Device for P96 output
Power Requirements Data logger’s 5 V supply
Current Drain
  • Up to 8 mA of additional current may be used by the DCE device connected to the SC105.
  • 0.16 mA (standby)
  • 1 to 4 mA (communicating)
Operating Temperature Range
  • -25° to +50ºC (standard)
  • -55° to +85°C (extended)
Operating Relative Humidity up to 95% (non-condensing)
Dimensions 2.3 x 4.3 x 9.2 cm (0.9 x 1.7 x 3.6 in.)
Weight 45.4 g (1.6 oz)

兼容性

Please note: The following shows notable compatibility information. It is not a comprehensive list of all compatible products.

数据采集器

Product Compatible Note
21X (retired) The 21X does not support direct output to a printer; use an SC932 for this purpose.
CR10 (retired)
CR10X (retired)
CR200X (retired)
CR206X (retired)
CR211X (retired)
CR216X (retired)
CR23X (retired)
CR295X (retired)
CR3000 (retired)
CR500 (retired)
CR5000 (retired)
CR510 (retired)
CR6
CR800 (retired)
CR850 (retired)
CR9000 (retired)

Additional Compatibility Information

Cable Connections and Mounts

Three cables (13657 Null Modem Cable, SC12 CS I/O Data Cable, and 10873 Serial Data Cable) are shipped with the SC105. The 13657 cable is used to program the device via a computer. The SC12 cable connects the SC105 to the data logger, and the 10873 cable connects the SC105 to the RS-232 DCE device. An SC12R-6 cable (purchased separately) may be used instead of the SC12 cable if a longer cable is required.

The 16987 mounting kit is available for attaching the SC105 to the backplate of an environmental enclosure.

Data Logger Considerations

Note: When using an SC105 with OS version 4 or newer with a mixed-array data logger, the data logger operating system should be updated to the latest released version.

下载

SC105 OS v.04 (573 KB) 28-08-2007

Current SC105 firmware. Requires the Device Configuration Utility and a 9-pin socket (female) to socket (female) NULL modem cable.

查看修订历史

Device Configuration Utility v.2.29 (54 MB) 15-11-2023

A software utility used to download operating systems and set up Campbell Scientific hardware. Also will update PakBus Graph and the Network Planner if they have been installed previously by another Campbell Scientific software package.

Supported Operating Systems:

Windows 11 or 10 (Both 32 and 64 bit)

查看修订历史

常见问题解答

SC105: 9

展开全部收起全部

  1. The SC105 uses the RS-232 standard, which is not compatible with multidrop communications (more than two devices on the same RS-232 bus). There are some third-party devices on the market that allow multiple devices to communicate over the same RS-232 link.

  2. Depending on what equipment is being used, a special interface may be required to attach a specific device to the data logger’s CS I/O port. In general, devices with a CS I/O port can be attached directly to the data logger’s CS I/O port. Devices with an RS-232 port require a special interface, such as the SC932A or SC105, to connect to the data logger’s CS I/O port.

  3. Both the computer’s serial port and the SC105’s RS-232 port are configured as data terminal equipment (DTE) devices. Because both components are DTE, a null modem cable is needed between them.

  4. The SC105 needs to be connected to the data logger’s CS I/O port, either directly or with the included SC12 cable. The SC105’s RS-232 port needs to be connected to the PC’s serial port using the included null modem cable.

  5. An RS-232 device cannot be directly connected to the CS I/O port of the data logger. A peripheral, such as an SC932A or SC105, is required.

  6. Using an SC105 with a RavenXTV or RavenXTG cellular modem allows for the two devices to communicate at differing baud rates. It also allows for other devices, such as an RF401 radio or CR1000KD handheld display, to simultaneously be connected to the data logger’s CS I/O port.

  7. The SC932A only is compatible with modem-enabled (ME) two-way communication between a data logger and a modem. In contrast, the SC105 is compatible with both ME and Synchronous Device for Communication (SDC) communications, as well as having the ability to internally buffer data.

  8. 一根 空 modem 线缆,一个 SC932A,一个 SC105,或 SC110 能够被用来连接 modem 到数据采集器。这些产品也能够被用来作为通讯接口连接串口传感器。关于更多信息请咨询 Campbell Scientific 的应用工程师。

案例研究

South Korea: Damage from Freezing Roads
Korea Expressway Corporation (KEC) was established in 1969 to construct and manage expressways throughout South......阅读更多

文章和新闻发布