停产的 ›
这个产品是无效的且被替换: HMP60-L.
HMP50-L Temperature and Relative Humidity Sensor
Services Available
Repair No
Calibration No
Free Support No

概览

The HMP50 measures both temperature and relative humidity and is suitable for long-term, unattended monitoring. The humidity component features a field-replaceable chip, which eliminates downtime typically required for the recalibration process. The HMP50 is compatible with all Campbell Scientific data loggers.

优势与特点

  • 野外可替换的湿度元件,消除了重校准的时间
  • 可被固定到直接塔/三脚塔的主桅杆或横臂上

图像

技术说明

The HMP50 measures temperature with a 1000 Ohm platinum resistance thermometer (PRT) and relative humidity (RH) with a 50Y Intercap capacitive chip. The chip is field-replaceable, which eliminates the downtime typically required for the recalibration process. This temperature and RH sensor is compatible with all Campbell Scientific data loggers.

The HMP50 should be housed in a solar radiation shield—typically the 41303-5A. The 41303-5A 6-plate naturally aspirated shield attaches to a mast, crossarm, or tower leg.

产品规格

Supply Voltage 7 to 28 Vdc (typically powered by data logger’s 12 V supply)
Current Consumption 2 mA (typical)
Housing Material Chrome-coated aluminum and chrome-coated ABS plastic
Operating Temperature Range -40° to +60°C
Diameter 1.2 cm (0.47 in.)
Length 7.1 cm (2.8 in.)
Weight 0.05 kg (0.1 lb) with 1.83-m (6-ft) cable

Relative Humidity

Sensor Vaisala’s INTERCAP capacitive chip
Measurement Range 0 to 98% RH (non-condensing)
Accuracy
  • ±3% (0% to 90% range)
  • ±5% (90% to 98% range)
Temperature Dependence See graph in product brochure.

Temperature

Temperature Sensor 1000 ohm Platinum Resistance Thermometer
Measurement Range -40° to +60°C
Accuracy See graph in product brochure.

兼容性

Please note: The following shows notable compatibility information. It is not a comprehensive list of all compatible products.

数据采集器

Product Compatible Note
21X (retired)
CR10 (retired)
CR10X (retired)
CR200X (retired)
CR206X (retired)
CR211X (retired)
CR216X (retired)
CR23X (retired)
CR295X (retired)
CR3000 (retired)
CR500 (retired)
CR5000 (retired)
CR510 (retired)
CR800 (retired)
CR850 (retired)
CR9000 (retired)

Additional Compatibility Information

Mounting

The HMP50 is typically housed in a 41303-5A 6-plate naturally aspirated shield.

It may also be housed in a 41003-5 10-plate shield if additional hardware is used. A 41322 Adapter Plate allows the HMP50 to be mounted in the lower part of the 41003-5 10-plate shield. Alternatively, a 41381 extension tube and the 6637 split nut plug can be used to mount the HMP50 in a higher part of the 41003-5; the #41381 cable is also required.

Both the 41303-5A and the 41003-5 attach to a crossarm, mast, or user-supplied pipe with a 1.0-in. to 2.1-in. outer diameter.

案例研究

District of Columbia: Solar Decathlon
The Solar Decathlon takes place every other year on the National Mall in Washington, D.C.......阅读更多
以色列: 红海海洋气象学
The meteorological stations at the Interuniversity Institute for Marine Sciences at Eilat (IUI) in Israel......阅读更多
Texas: College Weather Station
The Austin College Weather Station (ACWX) is located on Austin College's Sneed Environmental Research Area,......阅读更多