HMP60-L 空气温度/相对湿度探头
精确且坚实耐用
适用于长期的无人值守的应用
气象 应用支持 水资源 应用支持 能源 应用支持 湍流通量 应用支持 基础结构/工业设施 应用支持 土壤 应用支持

概览

HMP60测量0 到 100% RH范围内的相对湿度,和-40° to +60°C范围内的温度。这种探头适用于长期的无人值守的监测应用,与所有的坎贝尔数据采集器都兼容。

优势与特点

  • Field-replaceable humidity chip eliminates recalibration downtime
  • Compatible with most Campbell Scientific dataloggers
  • Can be mounted to a tower/tripod mast or crossarm

图像

HMP60
HMP60
HMP60
HMP60 with RAD06 mounted to a pole (items sold separately)

技术说明

HMP60 使用INTERCAP® 电容型RH芯片,可在野外更换RH芯片,消除了通常由重校准过程所导致的探头停止测量时间。

产品规格

Supply Voltage 5 to 28 Vdc (typically powered by datalogger’s 12 V supply)
Current Consumption
  • 1 mA (typical)
  • 5 mA (maximum)
Filter Description 0.2 µm Teflon membrane
Settling Time 1 s
Housing Classification IP65
Housing Material AISI 316 stainless steel
Filter Cap Material Chrome-coated ABS plastic
Field-Replaceable Chip or Recalibrate Field-replaceable chip (RH only)
Sensor Diameter 1.2 cm (0.5 in.)
Filter Diameter 1.2 cm (0.5 in.)
Length 7.1 cm (2.8 in.)
Weight 0.05 kg (0.1 lb) with 1.83 m (6 ft) cable

Relative Humidity

Sensing Element Vaisala’s INTERCAP capacitive chip
Measurement Range 0 to 100% RH (non-condensing)
Typical Accuracy at -40° to 0°C
  • ±5% (0 to 90% RH)
  • ±7% (90 to 100% RH)
Typical Accuracy at 0° to 40°C
  • ±3% (0 to 90% RH)
  • ±5% (90 to 100% RH)
Typical Accuracy at 40° to 60°C
  • ±5% (0 to 90% RH)
  • ±7% (90 to 100% RH)
Output Signal Range 0 to 1 Vdc

Air Temperature

Sensing Element 1000 ohm Platinum Resistance Thermometer (PRT)
Measurement Range -40° to +60°C
Accuracy ±0.6°C
Output Signal Range 0 to 1 Vdc

兼容性

Please note: The following shows notable compatibility information. It is not a comprehensive list of all compatible products.

数据采集器

Product Compatible Note
CR1000X (retired)
CR300 (retired)
CR3000 (retired)
CR310
CR350
CR6
CR800 (retired)
CR850 (retired)

Additional Compatibility Information

Mounting

When exposed to sunlight, the HMP60 must be housed in a 41303-5A, 41303-5B, or RAD06 6-plate naturally aspirated radiation shield. The 41303-5A and RAD06 attaches to a crossarm, mast, or user-supplied pipe with a 2.5 to 5.3 cm (1.0 to 2.1 in.) outer diameter. The 41303-5B attaches to a CM500-series pole or a user-supplied pole with a 5.1 cm (2.4 in.) outer diameter.

The RAD06 uses a double-louvered design that offers improved sensor protection from driving rain, snow, and insect intrusion, It also has lower self-heating in bright sunlight combined with higher temperatures (> 24°C [~75°F]) and low wind speeds (< 2 m s-1 [~4.5 mph]), giving a better measurement.


常见问题解答

HMP60-L: 4

展开全部收起全部

  1. The HMP60-L (with the Campbell Scientific cable) cannot be used with the 41003-5 10-Plate Radiation Shield without the use of additional hardware. For more information, refer to the Compatibility information on the HMP60-L product page. The standard radiation shield for the HMP60-L is the 41303-5A.

  2. In general, the element should be replaced every two years. By doing a field check (that is, comparing the RH reading with a reference), the element can be used until the relative humidity measurement is out of tolerance.

  3. The most significant difference is that the CS215-L has an SDI-12 output and that the HMP60-L has a voltage output. Additional differences are outlined in the “Air Temperature & Relative Humidity” brochure, which compares all of the Campbell Scientific temperature and relative humidity sensors. 

  4. Note the difference between calibration and a field check. Calibration cannot be done in the field, as it requires an experienced technician and specialized equipment.

    Field checks of measurements can be done to determine if the data make sense with the real-world conditions. Follow these steps to field check a sensor:

    1. Find a second sensor of the same type as the installed sensor whose data is in question. The second sensor will be used as a benchmark sensor and should be known to be accurate or recently calibrated.
    2. At the site, take readings using both sensors under the same conditions. The best practice is to measure both sensors side-by-side at the same time. Note that the sensors will never have the exact same measurement.
    3. Depending on the sensor model, if the difference in the readings of the installed and benchmark sensors is greater than the sum of the accuracies for both sensors, either return the installed sensor to Campbell Scientific for calibration or replace the appropriate chip.
      • The 107, 108, 109, 110PV-L, and BlackGlobe-L temperature sensors can be calibrated.
      • The HC2S3-L and HMP155A-L temperature and relative humidity sensors can be calibrated.
      • The CS215-L has a replaceable chip for temperature and relative humidity. For more information, refer to the “Maintenance and Calibration” section of the CS215 instruction manual.
      • The HMP60-L has a replaceable chip for relative humidity only. For more information, refer to the “Maintenance” section of the HMP60 instruction manual.