数据采集器 / CR350
CR350 测量和控制数据采集器
支持RS-485的紧凑型数据采集器
小型应用的理想之选
气象 应用支持 水资源 应用支持 能源 应用支持 湍流通量 应用支持 基础结构/工业设施 应用支持 土壤 应用支持

概览

CR350是一款多功能、极低功耗、紧凑型测量和控制数据采集器。这款入门级数据采集器拥有丰富的指令集,可以测量大多数水文、气象、环境和工业传感器。CR350可集中数据,通过各种网络提供数据,并使用您所需的协议进行传输。CR350还执行用于控制和M2M通信的自动化现场或远程决策。此数据采集器非常适合需要长期远程监控的小型应用程序。

以下介绍了 CR300, CR310, 和 CR350 数据采集器的主要区别:

  • The CR310 and CR350 offer removable connectors.
  • The CR310 includes a 10/100 Ethernet connection.
  • The CR350 has two independent RS-232/RS-485 ports and USB-C.

The CR350 includes Wi-Fi, cellular, or the following radio options for different regions:

  • CR350-RF407: US and Canada
  • CR350-RF412: Australia and New Zealand
  • CR350-RF422: Europe
  • CR350-RF427: Brazil

Note: Campbell Scientific does not recommend the CR350 for use as a PakBus router in networks with more than 50 devices. Large arrays or string variables may also reach memory limits. For such applications, a CR1000X Measurement and Control Datalogger is recommended.

优势与特点

  • 两个专用SDI-12端子,用于扩展SDI-12传感器的使用
  • 极低的电流要求
  • 两个专用RS-232/RS-485终端,支持智能传感器或调制解调器
  • 使用PC软件和USB-C连接的便捷设置
  • 能够测量模拟和数字传感器
  • 值得信赖的 Campbell Scientific 品质,集成浪涌和ESD保护
  • 集成电台选项,可无线连接到另一个节点或互联网网关
  • CR350-WIFI是短距离无线IP通信的理想选择
  • 可拆卸接线端子排,便于接线
  • 能够使用内置的蜂窝或卫星外围设备在任何地方进行通信
  • 集成太阳能电池充电调节器
  • 可灵活连接PakBus、Modbus、DNP3、GOES和其他标准通信协议
  • 多个通用I/O和可编程性,用于分析和控制测量采集
  • 事件驱动的通信和通知的物理输出

图像

技术说明

CR350是一款低功耗数据采集器,用于测量传感器、分析数据、存储数据和程序。内部锂电池维持时钟运行。主板上的类Basic编程语言和所有Campbell Scientific 的数据采集器一样,支持数据处理和分析。

端子说明

  • Two switched 12 V terminals (SW12V) for powering sensors or communication devices, 2100 mA 
  • Two sensor excitation or continuous 0.15 to 5 V terminals (VX1, VX2) for sensor excitation or output control
  • Four multipurpose analog input terminals (SE1–SE4)
    • Analog functions (SE1–SE4)
      • Analog inputs: 4 single-ended or 2 differential inputs with -100 to +2500 mV and ±34 mV ranges 24 bit ADC
      • 4 to 20 mA or 0 to 20 mA inputs (SE1, SE2 only)
    • Digital I/O functions (SE1–SE4) consist of 3.3 V logic levels for:
      • High frequency counter (35 kHz)
      • Pulse width modulation
      • Interrupts and timer input
      • Period average (200 kHz, amplitude dependent)
  • Two Pulse Counting Terminals (P_SW, P_LL)
    • P_SW
      • Switch closure (150 Hz)
      • High frequency counter (35 kHz)
    • P_LL
      • Low level ac (20 kHz)
      • High frequency counter (20 kHz)
  • Two Control Terminals (C1, C2): C terminals are software configurable for digital functions
    • Digital I/O functions consist of 5 V output and 3.3 V input logic levels for:
      • SDI-12
      • High frequency counter (3 kHz)
      • Switch closure (150 Hz)
      • General status/control voltage source 5 V; 10 mA @ 3.5 V
      • Interrupts
      • Serial asynchronous communication Tx/Rx pair

产品规格

Operating Temperature Range
  • -40° to +70°C
  • Non-condensing environment
Maximum Scan Rate 10 Hz
Case Material High-impact-resistant polycarbonate, recycle code 7
Analog Inputs 4 single-ended or 2 differential (individually configured)
Pulse Counters 8 (P_SW, P_LL, C1, C2, and SE1 to SE4)
Voltage Excitation Terminals 2 (VX1, VX2)
Communications Ports
  • USB Type C 2.0
  • RS-232
  • RS-485
Switched 12 Volt 2 terminals
Digital I/O 7 terminals (C1, C2, P_SW, and SE1 to SE4) configurable for digital input and output. Includes status high/low, pulse width modulation, external interrupt, and communication functions. Exception: C2 and P_SW don’t do pulse-width modulation.
Analog Input Limits -100 to +2500 mV
Analog Voltage Accuracy
  • Accuracy specifications do not include sensor or measurement noise.
  • ±(0.04% of measurement + offset) at 0° to 40°C
  • ±(0.1% of measurement + offset) at -40° to +70°C
ADC 24-bit
Power Requirements 16 to 32 Vdc for charger input (CHG) (Current limited to 1.1 A maximum for power converter or solar panel input.)
Real-Time Clock Accuracy ±3 min. per year
Internet Protocols Ethernet, PPP, RNDIS, ICMP/Ping, Auto-IP(APIPA), IPv4, IPv6, UDP, TCP, TLS (v1.2), DNS, DHCP, SLAAC, NTP, Telnet, HTTP(S), FTP(S), SMTP/TLS, POP3/TLS, MQTT(S)
Communication Protocols PakBus, PakBus Encryption, Modbus RTU/ASCII/TCP, DNP3, SDI-12, and others
CPU Drive/Programs 50 MB serial flash
Data Storage 50 MB serial flash
Idle Current Drain, Average 0.5 mA (@ 12 Vdc)
Active Current Drain, Average
  • < 1.5 mA (@ 12 Vdc for 1 Hz scan with 1 analog measurement)
  • 8 mA (@ 12 Vdc with processor always on)
Dimensions 16.3 x 8.4 x 5.6 cm (6.4 x 3.3 x 2.2 in.)
Additional clearance required for cables and leads.
Weight 288 to 306 g (0.64 to 0.68 lb) depending on communication option selected

CR350-RF407 Option

Radio Type Frequency Hopping Spread Spectrum (FHSS)
Output Power 5 to 250 mW (user-selectable)
Frequency 902 to 928 MHz (US, Canada)
RF Data Rate 200 kbps
Receive Sensitivity -101 dBm
Antenna Connector RPSMA (External antenna required; see www.campbellsci.com/order/rf407 for Campbell Scientific antennas.)
Idle Current Drain, Average 12 mA (@ 12 Vdc)
Active Current Drain, Average < 80 mA (@ 12 Vdc)

CR350-RF412 Option

Radio Type Frequency Hopping Spread Spectrum (FHSS)
Output Power 5 to 250 mW (user-selectable)
Frequency 915 to 928 MHz (Australia, New Zealand)
RF Data Rate 200 kbps
Receive Sensitivity -101 dBm
Antenna Connector RPSMA (External antenna required; see www.campbellsci.com/order/rf412 for Campbell Scientific antennas.)
Idle Current Drain, Average 12 mA (@ 12 Vdc)
Active Current Drain, Average < 80 mA (@ 12 Vdc)

CR350-RF422 Option

Radio Type 868 MHz SRD 860 with Listen Before Talk (LBT) and Automatic Frequency Agility (AFA)
Output Power 2 to 25 mW (user-selectable)
Frequency 863 to 870 MHz (European Union)
RF Data Rate 10 kbps
Receive Sensitivity -106 dBm
Antenna Connector RPSMA (External antenna required; see www.campbellsci.com/order/rf422 for Campbell Scientific antennas.)
Idle Current Drain, Average 9.5 mA
Active Current Drain, Average 20 mA

CR350-RF427 Option

Radio Type Frequency Hopping Spread Spectrum (FHSS)
Output Power 5 to 250 mW (user-selectable)
Frequency 902 to 907.5 MHz/915 to 928 MHz (Brazil)
RF Data Rate 200 kbps
Receive Sensitivity –101 dBm
Antenna Connector RPSMA (External antenna required)
Idle Current Drain, Average 12 mA (@ 12 Vdc)
Active Current Drain, Average < 80 mA (@ 12 Vdc)

CR350-RF452 Option

Radio Type Frequency Hopping Spread Spectrum (FHSS)
Output Power 10 mW to 1,000 mW (user-selectable)
Frequency 902 to 928 MHz
RF Data Rate 115.2 or 153.6 kbps
Receive Sensitivity
  • -108 dBm (@ 115.2 kbps for 10-4 BER
  • -103 dBm (@ 153.6 kbps for 10-4 BER
Antenna Connector RPSMA (External antenna required)
Idle Current Drain, Average < 29 mA (maximum @ 12 Vdc)
Active Current Drain, Average < 84 mA (maximum @ 12 Vdc)

CR350-WIFI Option

Operational Modes Client or Access Point
Operating Frequency 2.4 GHz, 20 MHz bandwidth
Antenna Connector Reverse Polarity SMA (RPSMA)
Antenna pn 16005 unity gain (0 dBd), 1/2 wave whip, omnidirectional with articulating knuckle joint for vertical or horizontal orientation
Transmit Power 7 to 18 dBm (5 to 63 mW)

CR350-CELL205 Option

-NOTE- The CR350-CELL205 option is not compatible with a Verizon cellular network.
Certifications IC (Industry Canada) 10224A-201611EC21A
Cell Technologies
  • 3G (UMTS/HSPA+)
  • 4G (LTE CAT-1)
3G Frequency Bands 850, 1700/2100 (AWS), and 1900
4G Frequency Bands 700, 850, 1700/2100 (AWS-1), 1900
Antenna Connector SMA (External antenna required; see www.campbellsci.com/order/cr350 for Campbell Scientific antennas.)
Power Consumption - Idle 14 mA (average)
Power Consumption - Active 75 mA (average)
SIM Interface 3FF (6 position/contacts)
Supports SIMs that require 1.8 or 3 V
Radio Output Power
  • 23 dBm on LTE
  • 24 dBm on UMTS
  • 27 dBm on EDGE
  • 33 dBm on GSM
Radio Sensitivity Range -99.5 to 110.5 dBm (10 M)

CR350-CELL210 Option

-NOTE- The CR350-CELL210 option is only compatible with a Verizon cellular network.
Cell Technologies 4G (LTE CAT-1)
4G Frequency Bands 700, 850, 1700, 1900, 2100
Antenna Connector SMA (External antenna required; see www.campbellsci.com/order/cr350 for Campbell Scientific antennas.)
Power Consumption - Low Power Mode 5 mA
Power Consumption - Idle 28 mA (average)
Power Consumption - Active 90 mA (average)
SIM Interface 3FF (6 position/contacts)
Supports SIMs that require 1.8 or 3 V
Radio Output Power 23 dBm on LTE
Radio Sensitivity Range -99.5 to 110.5 dBm (10 M)

CR350-CELL215 Option

-NOTE- The CR350-CELL215 option is intended for use in EMEA countries.
Cell Technologies
  • 2G (GSM/GPRS/EDGE)
  • 3G (UMTS/HSPA+)
  • 4G (LTE CAT-1)
2G Frequency Bands 900 and 1800 MHz
3G Frequency Bands 850, 900, and 2100 MHz
4G Frequency Bands 800, 850, 900, 1800, 2100, and 2600 MHz
Antenna Connector SMA (External antenna required; see www.campbellsci.com/order/cr350 for Campbell Scientific antennas.)
Power Consumption - Idle 14 mA (average)
Power Consumption - Active 75 mA (average)
SIM Interface 3FF (6 position/contacts)
Supports SIMs that require 1.8 or 3 V
Radio Output Power
  • 23 dBm on LTE
  • 24 dBm on UMTS
  • 27 dBm on EDGE
  • 33 dBm on GSM
Radio Sensitivity Range -99.5 to 110.5 dBm (10 M)

CR350-CELL220 Option

-NOTE- The CR350-CELL220 option is intended for use in Australia and New Zealand.
Cell Technologies
  • 3G (UMTS/HSPA+)
  • 4G (LTE CAT-1)
3G Frequency Bands
  • 850 and 2100 MHz (EC-21AUT)
  • 850, 900, 1900, and 2100 MHz (EC-21AU)
4G Frequency Bands
  • 700, 850, 1800, 2100, and 2600 MHz (EC-21AUT)
  • 700, 900, 1700, 1800, 1900, 2100, and 2600 MHz (EC-21AU)
Antenna Connector SMA (External antenna required; see www.campbellsci.com/order/cr350 for Campbell Scientific antennas.)
Power Consumption - Idle 14 mA (average)
Power Consumption - Active 75 mA (average)
SIM Interface 3FF (6 position/contacts)
Supports SIMs that require 1.8 or 3 V
Radio Output Power
  • 23 dBm on LTE
  • 24 dBm on UMTS
Radio Sensitivity Range -99.5 to 110.5 dBm (10 M)

CR350-CELL225 Option

-NOTE- The CR350-CELL225 option is intended for use in Japan.
Cell Technologies 4G (LTE CAT-1)
4G Frequency Bands 800 (lower), 800 (upper), 850+, 900, 1800, and 2100 MHz
Antenna Connector SMA (External antenna required; see www.campbellsci.com/order/cr350 for Campbell Scientific antennas.)
Power Consumption - Idle 14 mA (average)
Power Consumption - Active 75 mA (average)
SIM Interface 3FF (6 position/contacts)
Supports SIMs that require 1.8 or 3 V
Radio Output Power 23 dBm on LTE
Radio Sensitivity Range -99.5 to 110.5 dBm (10 M)

CR350-CELL230 Option

Cell Technologies LTE-Cat M, NB-IoT
Frequency Bands
  • LTE M B1/B2/B3/B4/B5/B8/ B12/B13/B18/B19/ B20/B25/B26/B27/B28/B66/B85
  • LTE NB-IoT B1/B2/B3/B4/B5/B8/ B12/B13/B18/B19/ B20/B25/B28/B66/B71/B85
Antenna Connector SMA (External antenna required; see www.campbellsci.com/order/cr350 for Campbell Scientific antennas.)
Power Consumption - Idle 23 mA average (26 mA if GPS is on)
Power Consumption - Active 50 mA average (53 mA if GPS is on)
SIM Interface 3FF (6 position/contacts)
Supports SIMs that require 1.8 or 3 V

兼容性

Please note: The following shows notable compatibility information. It is not a comprehensive list of all compatible products.

软件

Product Compatible Note
DevConfig Version 2.26 or higher
LoggerLink Version 1.5 or higher
LoggerNet Version 4.7 or higher
LoggerNet Mobile Connect Version 1.1 or higher
PC400 Version 4.7 or higher
RTDAQ
Short Cut Version 4.4 or higher

Additional Compatibility Information

Sensors

With several channel types, the CR350 is compatible with nearly every available sensor. This includes analog output voltage (0 to 2.5 V) and current (0 to 20 mA or 4 to 20 mA) sensors, thermistors, and RTDs to name a few. It is also compatible with pulse or frequency output sensors such as anemometers, rain gauges, and flow meters. CR350 dataloggers are not capable of applying reverse excitation, and they cannot be used with some conductivity or soil matric potential sensors.

SDI-12, Modbus, and other serial sensors are supported with the RS-232 port and C1 and C2 as a Tx/Rx pair. The CR350 also supports true RS-232 and RS-485 on COM2 and COM3, along with a dedicated RS-232 DB9 port.

Measurement & Control Peripherals

The CR350 is compatible with low current and voltage solid-state relays but not with SDM or CDM devices.

Software

The CR350 series is compatible with CRBasic (version 3.6 or higher).

Enclosures

An ENC10/12 or ENC12/14 enclosure is adequate for most CR350-based systems.

Communications

The CR350 can communicate with a PC directly via its USB port. Compatible telemetry devices include our RS-485 converters, digital cellular gateways, RF telemetry, and satellite transmitters (HDR GOES, Argos, Meteosat, Iridium, and Inmarsat). Data can be viewed on an iOS or Android device (requires our free LoggerLink app), CD295 DataView II Display, or other third-party devices.

Data Logger Option Communications Type Integrated Communications Are Compatible with

CR350-WIFI

2.4 GHz, 20 MHz bandwidth

Most other Wi-Fi devices, such as the CR310-WIFI, CR300-WIFICR6-WIFI, NL240

CR350-RF407

902 to 928 MHz Frequency Hopping Spread Spectrum

RF407, CR6-RF407, CRVW3-RF407

CR350-RF412

915 to 928 MHz Frequency Hopping Spread Spectrum

RF412, CR6-RF412, CRVW3-RF412

CR350-RF422

868 MHz SRD860 LBT+AFA

RF422, CR6-RF422, CRVW3-RF422

CR350-CELL

2G Frequency Bands 850, 900, 1800, 1900

3G/4G Frequency Bands 800, 850, 900, 1900, 2100

GSM/GPRS/EDGE (2G)

UMTS/HSPA+ (3G)

LTE (4G)

Power

The CR350 uses an external power source and has a built-in charger/regulator. Intelligent power sourcing autoselects the highest voltage from three input sources (CHG, BAT, or USB) to operate in one of the following four modes:

  • UPS (recommended) - A 16 to 32 Vdc source, solar panel (SP10, SP20), or power converter (29796) is used to charge a 12 Vdc battery, such as our BP7 or BP12.
  • 12 Vdc battery or other reliable 12 Vdc source
  • Charge only - DC power supply (16 to 32 Vdc)
  • USB - Powered over 5 Vdc USB port for setup, programming, and testing (will not charge battery or boost USB power to provide 12 Vdc to the switched battery terminal SW12)

视频与教程

下载

CR350 OS v.01.05 (5.00 MB) 21-02-2024

This download is for the CR350 datalogger. Execution of this download places the Operating System file(.obj) on your computer. It also updates the CRBasic Editor compiler and support files. 

Why Update? This OS fixes issues related to the TX325/TX326, SDI12Recorder and MQTT along with other fixes and new features. See the revision history for a complete list. With this OS update, it is recommended that you also update the Device Configuration Utility to the most recent version so that new datalogger features are available in the utility.  

Note/Warning: Campbell Scientific always recommends updating operating systems on site if possible. When remote updates are required, it is recommended that you implement the necessary precautions to handle unexpected OS upload complications. All datalogger settings should be retained when updated remotely. If you choose to roll back to a previous operating system, the datalogger settings will be reset to default.

Watch the Video Tutorial: Sending an OS to a Local Datalogger.

查看修订历史

Data Logger Wiring Excel Template (1 KB) 26-03-2024

This is a data logger wiring diagram spreadsheet template that accompanies the Wiring Diagram Video. The spreadsheet includes templates for  CR6, CR1000X, CR300, CR310, and CR350 data loggers. The file is an Excel template and works best with Microsoft Excel. 

常见问题解答

CR350: 1