数码相机 / CC5MPX
停产的 ›
这个产品是无效的且被替换: CCFC.
CC5MPX 数码照相机
Services Available
Repair No
Free Support Yes

概览

CC5MPX 高精度数码网络照相机,带有摄像功能。耗电低。照相机可输出5百万像素的图像,外壳非常坚固耐用可在野外极端温度下使用。与Campbell Scientific数据采集器兼容,可选择使用SD存储卡存储数据。

优势与特点

  • High-quality; designed for outdoor observation in remote locations
  • Low power consumption
  • Operates with AC power or solar power battery if AC is unavailable
  • Can be controlled by internal timer or by external controls: motion detector, web page, data logger
  • Various communications options available; can publish images and video directly to the web or send images to your desktop
  • Designed to work in harsh environments, this camera operates at temperatures as low as -40°C and as high as 60°C
  • Type 3 anodization for improved performance in corrosive environments

图像

技术说明

CC5MPX 高分辨率数码网络照相机,带有摄像功能。耗电低,电池功能。照相机可输出5百万像素的图像,720P分辨率的视频。可以作为一个独立的照相机也可以连接到数据采集器上,或者连接到PakBus®设备上。多种供电模式,使其可以在偏远地区靠电池供电情况下使用。

CC5MPX 可在恶劣的环境下使用,操作温度范围为-40°C 至60°C。安装在环保密封机箱中,可以保护照相机免受水汽和高湿度的侵袭。集成式机箱也免去了将照相机安装在独立机箱中的时间。

CC5MPX图像采集和存储可以有好几种选择。用户可以根据内部定时器,内部检测器,连到外部PakBus设备(例如数据采集器)上的触发器来实现抓取图像或录像。图像或视频可以存储在SD卡中,存在数据采集器中,通过email或FTP端传至电脑上。

产品规格

Operating Power 9 to 30 Vdc
Operating Temperature Range -40° to +60°C
Clock Accuracy ±2 minutes per year (-40° to +60°C)
Photo or Video Capture Triggers Two independent self timers, external trigger, motion detection, web page control
Programmable Still Image Resolutions
  • 2592 x 1944 (JPEG)
  • 1280 x 960 (JPEG)
  • 1280 x 720 (JPEG)
  • 640 x 480 (JPEG)
  • 640 x 352 (JPEG)
  • 320 x 240 (JPEG)
  • 320 x 176 (JPEG)
Video Capable of up to 720P for the following:
  • 1280 x 720 (MPEG4)
  • 640 x 480 (MJPEG)
  • 320 x 240 (MPEG4)
Video Frame Rate Options 30, 15, and 7.5 FPS (Frames Per Second)
Communication Interfaces RS-232 port, RS-485 port, Ethernet 10/100
Communications Protocols PakBus, FTP, email, web page interface via web browser
Maximum Baud Rate 115.2 kbps (for RS-232 and RS-485 only)
Window Defroster No
Wi-Fi Capable No
Low-Light Capability Not designed for low-light conditions.
NDVI Capability No
Diameter 9.3 cm (3.7 in.)
Length 22 cm (8.7 in.)
Weight 1.06 kg (2.34 lb)

Communication Switched Power Output

Maximum Output Current 750 mA

Current Drain

Maximum 250 mA (at 12 Vdc)
Quiescent ≤ 1 mA (off power mode)

Lens

Mount C-type
IRIS DC compatible
Standard Lens 4 to 12 mm, 27° to 80° FOV

External Input Signal

Logic Low Level 0.65 Vdc (-20 Vdc absolute minimum)
Logic High Level > 2.0 Vdc (+20 Vdc absolute maximum)
Minimum Pulse Width 10 ms

Memory Card Interface

Type Secure Digital (SD)
File System FAT32
File Type JPEG (image), AVI (video)
Size 16 GB or less

Photo Capture Time

-NOTE- Time is from wake-up to start of capture.
Fully On < 1 s (5 MP images take longer.)
Partially On 10 s
Deep Sleep 15 s
Off State 90 s

兼容性

Please note: The following shows notable compatibility information. It is not a comprehensive list of all compatible products.

数据采集器

Product Compatible Note
21X (retired)
CR10 (retired)
CR1000X
CR10X (retired) The CR10X must be the -2M version and must use the PakBus operating system.
CR200X (retired)
CR206X (retired)
CR211X (retired)
CR216X (retired)
CR23X (retired) The CR23X must be the -2M version and must use the PakBus operating system.
CR295X (retired)
CR300 Limited to RS-232 Port with Null Modem, NO USR Drive Capability.
CR3000 (retired)
CR310
CR500 (retired)
CR5000 (retired)
CR510 (retired) The CR50 must be the -2M version and must use the PakBus operating system.
CR6
CR800 (retired)
CR850 (retired)
CR9000 (retired)

Additional Compatibility Information

Mounting

The 18549 Camera Mounting Kit is used to mount the CC5MPX camera to a CM202, CM204, or CM206 crossarm. The crossarm then attaches to a tripod, tower, or user-supplied pole (1.0-in. to 2.1-in. outer diameter). The bracket’s design facilitates the aiming of the camera.

Data Logger Considerations

The CC5MPX camera is compatible with any PakBus data logger that has 2 MB or greater of on-board memory. The data logger must have a current operating system.

Connections

The CC5MPXCBL1 Power and I/O Cable connects the camera to:

  • Power supply
  • COM port of a CR800, CR850, CR1000, or CR3000 datalogger
  • MD485 Multidrop Modem (for connecting more than one camera to a data logger or if long cable lengths are required)
  • PC (for configuring camera via the Device Configuration utility; also requires the DB9M-TERM interface that is shipped with the camera)

An Ethernet cable is required to configure the camera. Typically, the CC5MPXCBL2 Environmental Cable is used. The Ethernet cable connects the camera to a network router, cellular modem, or laptop. With this connection, the user can access a web interface that:

  • Allows adjustment of camera targeting/focusing
  • Supports camera configuration
  • Displays camera information, system status, date and time

下载

CC5MPX OS v.1.25.1 (13.8 MB) 24-06-2019

Current CC5MPX Camera Operating System.

Note: Do not extract the firmware update file “CC5MPX_FW_1_25_1.tar.gz”.This compressed file gets sent to the CC5MPX as is.

查看修订历史

CC5MPX PIC OS v.2.0 (18 Kb) 18-11-2014

Current firmware for the CC5MPX Peripheral Interface Controller (PIC)

Note: In order for the CC5MPX to accept the PIC firmware the CC5MPX OS 1.23 or higher must be running in the camera. Retrieve the CC5MPX_PIC_UPDATE_V2_JUNE_17_2014.hex.gz firmware from the .zip file. Do not extract the firmware update file "CC5MPX_PIC_UPDATE_V2_JUNE_17_2014.hex.gz". This compressed file must be sent to the CC5MPX as a “.gz” file.  Details related to updating firmware can be found in the CC5MPX manual.

常见问题解答

CC5MPX: 14

展开全部收起全部

  1. The idle timeout on the FTP server is set for 15 minutes. If the server doesn’t see any communication from the client within 15 minutes, it will close the connection.
  2. This depends. Typically, most camera applications require an environmentally sealed cable, such as the CC5MPXCBL2-L, rather than a generic Ethernet cable. However, for indoor or temporary applications where the cable will not be exposed to weather elements, use a standard 10Base-T CAT5e Ethernet cable, such as pn 28900.

  3. This may be possible. Contact Campbell Scientific for assistance with this.

  4. PoE, or Power over Ethernet, is commonly used as a way to power devices and equipment using the unused conductors in a standard Ethernet cable. To accomplish this, there must be a sending device, or power source equipment, as well as a powered device.

    The CC5MPX family of cameras does not work with PoE. For the family of CC5MPX cameras to be powered, a separate accessory, the CC5MPXCBL1-L cable, must be used to provide both power and RS-232/RS-485 communications.

  5. The CC5MPXCBL2-L is an environmentally sealed Ethernet (RJ45) cable that provides access to the network functionalities of the CC5MPX family of cameras. This cable is used with a camera to do the following: send emails, transfer images via FTP (accessing either a web server or an optional internal SD memory card), synchronize with a network time server, or gain access to the camera’s configuration web page. The CC5MPXCBL2-L can also be used to connect the CC5MPX directly to an Ethernet port, such as a cellular modem or wireless router. In addition, Campbell Scientific recommends using this cable if the CC5MPX is mounted on a tall tower or in a location that is not easily accessible.

    Note: The camera’s internally served configuration web page is the only way to view the real-time streaming video that is used to manually zoom and focus the camera.

  6. This is done by sending images via PakBus to a Campbell Scientific data logger with a cellular modem telemetry option. The cable that is used is the CC5MPXCBL1-L Power and I/O Cable, which provides power from the data logger, as well as an RS-232 or RS-485 connection.

  7. The CC5MPX uses a standard C-Type mount lens. If a lens fits within the lens tube barrel, or if the camera will be used in an environment where the front lens tube barrel is unnecessary, other lenses, such as a zoom or fisheye may be used.

    Note: Use of an alternate lens may void the product warranty.

  8. No. A data logger is not necessary if the CC5MPX will be used in a stand-alone mode. In essence, a camera that is used without a data logger is an IP web camera. The camera does, however, need access to a 9 to 30 Vdc power supply.

  9. Images can be obtained from the CC5MPX’s Ethernet connection through either FTP or email.

  10. Although the CC5MPX’s enclosure is weather resistant, it is not designed for underwater use. However, if a watertight enclosure is rated suitable for saltwater environments, and there is physical space for the CC5MPX within the enclosure, then the camera will function as designed.

    Note: Campbell Scientific does not offer any watertight enclosures rated suitable for saltwater environments.


文章和新闻发布