CNR1净辐射表由Kipp & Zonen生产,适用于那些需要研究级性能的应用中。CNR1用于监测能量平衡,测量4个辐射分量:入射短波辐射、入射长波辐射及地表反射短波辐射和地表长波辐射。在结构上,CNR1含有一对朝上的短波辐射表和长波辐射表,以及镜像对称的一对朝下的短波辐射表和长波辐射。短波表和长波表分别测量短波辐射和远红外辐射。CNR1还含有一个铂电阻,用于测量辐射表内部温度;还有一个加热器用于防止凝结。CNR1-L的线缆长度根据订单要求而定。当订购CNR1时,标准的线缆长度为82英尺。
如果需要CNR1或CNR1-L的固定支架,请点击右侧的 Ask an Expert 标签获取建议;或者电话 435-227-9000 向我们通量组的某位成员寻求帮助。
CNR1-L的线缆长度由用户指定。该净辐射表适用于要求研究级性能的应用中。CNR1用于监测能量平衡,测量4个辐射分量:入射短波辐射、入射长波辐射及地表反射短波辐射和地表长波辐射。
在结构上,CNR1含有一对朝上的短波辐射表和长波辐射表,以及镜像对称的一对朝下的短波辐射表和长波辐射。短波表和长波表分别测量短波辐射和远红外辐射。4个探头单独校准,具有各自的灵敏度系数。
CNR1还含有一个铂电阻,用于测量辐射表内部温度;还有一个加热器用于防止凝结。
CNR1占用数据采集器上的6对差分通道,或4个单端加上2对差分通道。具有足够模拟通道的数据采集器包括:CR1000、CR3000和CR5000。
如果需要CNR1或CNR1-L的固定支架,请点击右侧的 Ask an Expert 标签获取建议;或者电话 435-227-9000 向我们通量组的某位成员寻求帮助。
Sensors | Kipp & Zonen’s CM3 ISO-class, thermopile pyranometer, CG3 pyrgeometer, PT100 RTD |
Pyranometer Spectral Response | 305 to 2800 nm |
Pyrgeometer Spectral Response | 5000 to 50,000 nm |
Response Time | 18 s |
Sensitivity Range | 7 to 15 μV W-1 m2 |
Pyranometer Output Range | 0 to 25 mV |
Pyrgeometer Output Range | ±5 mV |
Expected Accuracy for Daily Totals | ±10% |
Directional Error | < 25 W m2 (pyranometer) |
Heating Resistor | 24 ohm, 6 W (at 12 Vdc) |
CE Compliance | CE compliant under the European Union’s EMC directive |
操作温度范围 | -40° to +70°C |
Dimensions | 23.2 x 8.0 x 15.6 cm (9.1 x 3.1 x 6.1 in.) |
Weight | 4 kg (8.8 lb) |
Please note: The following shows notable compatibility information. It is not a comprehensive list of all compatible products.
Product | Compatible | Note |
---|---|---|
21X (retired) | ||
CR10 (retired) | ||
CR10X (retired) | ||
CR200X (retired) | ||
CR206X (retired) | ||
CR211X (retired) | ||
CR216X (retired) | ||
CR23X (retired) | ||
CR295X (retired) | ||
CR3000 (retired) | ||
CR500 (retired) | ||
CR5000 (retired) | ||
CR510 (retired) | ||
CR800 (retired) | ||
CR850 (retired) | ||
CR9000 (retired) |
Do Not use the UT018 crossarm with the 14364 mounting bracket to fasten the CNR1 to a tower leg. The 14264 mounting bracket should be attached directly to a vertical pole.
Data Logger Requirements: Six differential or four single-ended and two differential analog channels.
CNR1-L: 2
Only one 4WPB100 is needed to measure the internal PRT in the radiometer.
The CR1000 requires a 4WPB100 to measure the internal PRT. (Data loggers such as the CR3000 and CR5000 have the necessary PRT bridge module built in to measure the PRT.) Note that the CNR4-L also includes an internal thermistor, which can be directly measured by the CR1000. Because of this, when using a CR1000, Campbell Scientific typically recommends monitoring the internal temperature of the CNR4-L using its internal thermistor instead of the PRT.