SDM-CAN SDM- CAN 数据接口模块
Services Available

概览

SDM-CAN组件可以使Campbell Scientific的数据采集器直接从CAN总线网络采集数据。通过数据采集器输入通道,使基于CAN总线的数据测试和验证在测量时独立的完成,SDM-CAN 组件同时还支持将数据传输到CAN总线网络。

优势与特点

  • Supports various CAN modes
  • Uses latest Philips CAN controller
  • Can be used in many networking applications, including vehicle testing

图像

技术说明

CANbus data can be stored (and synchronized) with other data values measured directly by the data logger, allowing testing and verification of CANbus-based data alongside measurements made independently via the data logger's input channels. The SDM-CAN also supports transmission of data onto a CANbus network.

The SDM-CAN uses the latest Philips SJA1000 CAN controller clocked at 16 MHz; CAN 2.0A and 2.0B active and passive modes are supported, which includes SAE J1939. The CANbus protocol is used in a number of networking applications, including vehicle data acquisition systems (VDAS).

The SDM-CAN can act as a passive “listen-only” device, poll remote devices for data, or act as a sensor. To poll remote devices it sends or responds to Remote Frame Requests.  It acts as a sensor by sending data packets to the CANbus network. The SDM-CAN supports baud rates up to 1 MB (1 M, 800 k, 500 k, 250 k, 125 k, 50 k, 20 k, and lower). Non-standard baud rates may be possible. CAN data frames can also be built and sent.

The data logger enables individual modules through an addressing scheme; up to 15 SDM-CANs can be connected to one data logger.

SDM-CAN Helper

SDM-CAN Helper is an add-on program for our RTDAQ Real-Time Data Acquisition Software. This add-on program walks users through the process of configuring their SDM-CAN, connecting the SDM-CAN to the data logger, sending an appropriate program to the data logger, and setting up their data logger to collect specific values from the CANbus network.

SDM-CAN Helper is available, at no charge, from the Downloads section. Users must have a valid installation of RTDAQ on their computer to install the SDM-CAN Helper program.

产品规格

Function Allows a data logger to sample data directly from a CANbus communication network. Uses latest CAN controller.
Number of Channels 1
Operating Temperature Tested from -40° to +80°C.
Operating Voltage 7 to 26 Vdc
Isolation Optional (switch-selectable) galvanic isolation between the data logger and the CANbus. The minimum isolation breakdown is 50 V; this barrier is for signal isolation only (that is, it is not a safety barrier).
Controller Uses the latest Philips SJA1000 CAN controller clocked at 16 MHz.
CANbus Physical Connection Conforms to CIA draft standard 102 version 2, 9-pin D connector. (The interface will differ from this standard only with respect to pin 9, which outputs 5 Vdc instead of 7 to 13 Vdc.)
Screw Terminal Block A three-way, unpluggable screw terminal block for CAN High, Low, and G is provided.
Safety For safety reasons, can disable CANbus transmit and acknowledge via a jumper (for example, for in-vehicle, listen-only monitoring)
Dimensions
  • The device can be vertically mounted with all the connectors on the top surface.
  • 17.5 x 10.0 x 2.3 cm (6.9 x 3.9 x 0.9 in.)
Weight 0.3 kg (0.14 lb)

Typical Current Consumption

Active in Self-Powered, Isolated Mode
  • 70 mA (recessive state)
  • 120 mA (dominant state)
Active, Non-Isolated
  • 30 mA (recessive state)
  • 70 mA (dominant state)
Standby < 1 mA (with or without isolation)
Communications with Data Logger 50 mA
RS-232 Port Active 50 mA

兼容性

Please note: The following shows notable compatibility information. It is not a comprehensive list of all compatible products.

数据采集器

Product Compatible Note
21X (retired)
CR10 (retired)
CR1000X
CR10X (retired)
CR200 (retired)
CR200X (retired)
CR205 (retired)
CR206 (retired)
CR206X (retired)
CR210 (retired)
CR211 (retired)
CR211X (retired)
CR215 (retired)
CR216 (retired)
CR216X (retired)
CR23X (retired)
CR295 (retired)
CR295X (retired)
CR300
CR3000 (retired) For the CR3000, SDMs are connected to the ports labeled SDM-C1, SDM-C2, and SDM-C3.
CR310
CR350
CR500 (retired)
CR5000 (retired) For the CR5000, SDMs are connected to the ports labeled SDM-C1, SDM-C2, and SDM-C3.
CR510 (retired)
CR6
CR800 (retired)
CR850 (retired)
CR9000 (retired) For the CR9000, SDMs connect to ports provided on the CR9080 PAM module.

Distributed Data Acquisition

Product Compatible Note
Granite 10
Granite 6
Granite 9

Additional Compatibility Information

Data Logger Considerations

Programming

Data is transferred between the SDM-CAN interface and the data logger using Campbell Scientific’s high-speed SDM communications protocol. The CANBUS Instruction controls the SDM-CAN operation in CRBasic; Instruction 118 controls the SDM-CAN operation in Edlog.

Power Considerations

The SDM-CAN draws 1 mA quiescent, up to 120 mA active. The data logger's sealed rechargeable power supply (or an external one) connected to a continuous charging source is recommended.

Enclosures

The SDM-CAN requires a desiccated, non-condensing environment; a Campbell Scientific enclosure is recommended. The SDM-CAN has built-in keyhole flanges for mounting to the backplates of Campbell Scientific enclosures.

下载

SDM-CAN OS v.4 (612 KB) 21-11-2006

Current version of the SDM-CAN firmware.

SDM-CAN Helper v.1.1 (59.5 MB) 29-09-2016

Add-on package for RTDAQ. Assists users of the SDM-CAN device.

See the SDM-CAN Helper Overview for more information about this product.

Note: The SDM-CAN Helper will only be installed if a valid installation of RTDAQ already exists on the computer.

查看修订历史

常见问题解答

SDM-CAN: 3

展开全部收起全部

  1. 不行,需要一个RS-422-至-CAN网关设备。

  2. Four byte IEEE4 (floating point) decoding can be handled Up to 24 bit signed and unsigned integer decoding can be handled. However, there are methods to use byte math in the data logger program code to decode CAN frame integer data values larger than 24 bits.

  3. 是的,在一些协议案例中可以实现。