概览

NL120 可让我们的数据采集器通过局域网进行通讯,或通过TCP/IP进行专用的互联网连接。这种小巧且坚实耐用的通讯设备连接到CR1000 或 CR3000数据采集器的40-针外设端口上。

优势与特点

  • Compatible with CR1000 and CR3000
  • Connects a data logger to a network
  • Smallest Ethernet module available for the CR1000 and CR3000

图像

技术说明

NL120 使用10baseT 的以太网直通线缆,从集线器连接到NL120;使用10baseT 的以太网交叉线缆,如果直接从计算机连接到NL120。对于线缆长度大于 9英尺的情形,需要使用带屏蔽的10baseT 的以太网线缆,或28033电涌防护器。

使用设备配置应用软件(DevConfig)来设置NL120。DevConfig捆绑在PC400、LoggerNet和RTDAQ里面。DevConfig 还能免费下载,网址是www.campbellsci.com/downloads。

产品规格

Power Requirements 12 V (supplied through the data logger’s peripheral port)
Ethernet Speed 10Base-T (10 Mbps), half-duplex
Typical Current Drain 20 mA
Dimensions 10.2 x 6.4 x 2.8 cm (4.0 x 2.5 x 1.1 in.)
Weight 66.62 g (2.35 oz)

EMI and ESD Protection

European Standards Meets requirements for a class A device under European Standards.
Application of Council Directive(s) 89/336/EEC as amended by 89/336/EEC and 93/68/EEC
Standards to Which Conformity Is Declared EN55022-1; 1995 and EN50082-1: 1992

Software Requirements

LoggerNet Version 3.2 or later
PC400 Version 1.3 or later
DevConfig Version 1.5 or later

兼容性

Please note: The following shows notable compatibility information. It is not a comprehensive list of all compatible products.

数据采集器

Product Compatible Note
CR200X (retired)
CR206X (retired)
CR211X (retired)
CR216X (retired)
CR295X (retired)
CR3000 (retired)
CR3000 (retired)
CR5000 (retired)
CR800 (retired)
CR850 (retired)

固定设备

Product Compatible Note
ENC10/12
ENC10/12R Attached to a CR1000 or CR3000
ENC12/14 Attached to a CR1000
ENC14/16 Attached to a CR1000 or CR3000
ENC16/18 Attached to a CR1000 or CR3000

Additional Compatibility Information

Ethernet Cable

A 10baseT Ethernet straight through cable is used when the cable is run from a hub to the NL120. A 10baseT Ethernet crossover cable is used if the cable is run directly from the computer to the NL120. For cable length longer than 9 ft, the 10baseT Ethernet cable must be shielded or the 28033 surge suppressor must be used.

Data Logger Considerations

The NL120 fastens onto the data logger's 40-pin peripheral port. This means that the NL120 is only compatible with the CR1000 and CR3000. It is NOT compatible with the CR800, CR850, CR200X, CR5000, or CR9000X dataloggers.

相关技术文档

产品样册

案例研究



常见问题解答

NL120: 23

展开全部收起全部

  1. The NL120 is a communications peripheral only. It does not provide additional analog terminals for a data logger.

  2. Yes. The NL120 operates as transparent.

  3. Yes, the NL120 can be repaired. Refer to the Repair and Calibration page for the process of returning equipment to Campbell Scientific.

  4. The PakBus protocol allows multiple simultaneous connections. The PakBus address that LoggerNet uses for itself on one of the PCs needs to be changed, though.

  5. There is no separate firmware for the NL120. It is built into the main data logger’s operating system.

  6. Yes. By configuring the NL120 as a CSDC device, both the NL120 and COM320 can share the same CS I/O port. The CR1000 and CR3000 are capable of multi-threading, so the NL120 and COM320 can run in parallel. For more information, refer to the NL120 Ethernet Module Instruction Manual.

案例研究

南达科他州:熔岩监测
America currently has an estimated 75,000 tons of spent nuclear fuel housed at dozens of......阅读更多
安大略: 太阳能项目
With climate change and pollution becoming important issues globally, it is important for governments and......阅读更多
Ontario: Green Roofs
The Problem—How to optimize green-roof performance The University of Toronto's Green Roof Innovation Testing Laboratory (GRIT......阅读更多
阿肯色州:洪水预警
Hot Springs, Arkansas, is a history-rich city located adjacent to Hot Springs National Park. The......阅读更多
北卡罗莱纳州: “绿色”酒店监测系统
When Dennis Quaintance decided to build the Proximity Hotel in Greensboro, North Carolina, he knew......阅读更多
犹他州: 供水系统
In 2010, Trenton and Amalga, two northern Utah towns separated by only a few miles,......阅读更多