ENC10/12为耐候机箱,宽10英寸,高12英寸。它是我们标准机箱系列中最小和最便宜的。可容纳一个小一些的数据采集器,一个供电电源和一个小外设。或者可用来安置需要独立于数据采集器机箱的一个外设。
请注意,机箱不包括接地线。
ENC10/12机箱内的底板以1/2英寸等间距的网格预先打好了孔,适合安装数据采集器、供电电源、以及通讯或测量控制外设。
ENC10/12发运时带有7363机箱配件包,含有干燥剂、湿度指示卡片、绑扎线、固定线缆粘块、灰泥、护线套、螺丝、PVC耦合连接。另外,Campbell Scientific供应CS210机箱内湿度传感器用于监测机箱内的相对湿度(见订货信息)。
Color | White (Reflects solar radiation, reducing temperature gradients inside the enclosure without using a separate radiation shield.) |
Construction | Fiberglass-reinforced polyester enclosure with door gasket, external grounding lug, stainless-steel hinge, and lockable hasps |
Enclosure Classification | NEMA 4X (before being modified for cable entry) |
Number of Cable-Entry Seals | 1 medium, 2 small |
Dimensions |
|
Weight | 4.1 kg (9.0 lb) |
Please note: The following shows notable compatibility information. It is not a comprehensive list of all compatible products.
Product | Compatible | Note |
---|---|---|
21X (retired) | ||
CR10 (retired) | ||
CR10X (retired) | ||
CR200X (retired) | ||
CR206X (retired) | ||
CR211X (retired) | ||
CR216X (retired) | ||
CR23X (retired) | ||
CR295X (retired) | ||
CR300 | ||
CR3000 (retired) | The ENC10/12 is compatible with the CR3000 using the -NB option (base with no battery). Similar to the CR800/CR850 and CR1000, the CR3000 must be mounted vertically rather than horizontally. No space remains in the enclosure for additional peripherals. | |
CR350 | ||
CR500 (retired) | ||
CR5000 (retired) | ||
CR510 (retired) | ||
CR6 | ||
CR800 (retired) | Although the CR800 is compatible, this data logger can only fit inside the ENC10/12 if it is mounted vertically rather than horizontally. | |
CR850 (retired) | Although the CR850 is compatible, this data logger can only fit inside the ENC10/12 if it is mounted vertically rather than horizontally. | |
CR9000 (retired) |
Retired peripherals that won’t fit in the same ENC10/12 enclosure as the data logger/power supply include the AVW4, AM416, COM100, CR10KD, DC1765, and RC35.
ENC10/12: 15
展开全部收起全部
If you purchased a Stahlin enclosure from Campbell Scientific and it has a failed gasket, we can help you. We will need you to provide an image of the failed gasket, verify the size of your enclosure, and provide your contact information. We can then arrange to have a replacement gasket sent to you from Stahlin. For assistance, contact Technical Support at 435.227.9100.
The following information is applicable to many of Campbell Scientific’s standard enclosures and prewired enclosures.
Note: The procedure below will not work for torn or damaged seals.
To make a field repair to a loose gasket on an enclosure, first acquire an adhesive, such as standard Gorilla Glue, that is rated for use with polyurethane foam. The adhesive should be compatible with, and recommended for, use with polyurethane foam. Follow these steps: