AM25T 25通道固态扩展板
连接多个热电偶
多个AM25T可连接到
一个数据采集器上
气象 应用支持 水资源 应用支持 能源 应用支持 湍流通量 应用支持 基础结构/工业设施 应用支持 土壤 应用支持

概览

AM25T 25通道固态扩展板可增加连接的热电偶的数量。扩展板接口与数据采集器相连接,为热电偶或其它低电压输出的传感器提供更多的端子接口。

优势与特点

  • Greatly increases the number of thermocouples a data logger can measure
  • Multiplexes up to 25 thermocouples
  • Includes an on-board PRT that serves as a reference junction
  • Allows several AM25Ts to be controlled by one data logger, increasing the number of thermocouples that can be measured
  • Uses a metallic, internal ground plane to reduce thermal gradients, which ensures more accurate measurements
  • Provides a vertical package for a smaller “footprint” that makes it easier to fit in a crowded enclosure
  • Supports a maximum cable length of 152.4 m (500 ft) when lightning protection is used

图像

Footprint for mounting

3D/CAD 文件:

技术说明

AM25T利用不同的通道最多可次序连接25个热电偶,通道输出接线至数据采集器不同的输入通道。AM25T 次序改变通道,数据采集器按顺序测量每个热电偶的输出信号。

AM25T’s 接地排带有参比温度探棒,为热电偶测量提供温度参比。接地排的热容和绝缘铝外膜可减小扩展板的热梯度。热梯度的减小可使测量更精确。

产品规格

Expandability
  • Assumes sequential activation of multiplexers and that each data logger channel is uniquely dedicated.
  • 1 AM25T per CR300 or CR310 (requires OS version 6 or later)
  • 2 AM25Ts per CR800 or CR850
  • 3 AM25Ts per CR6
  • 4 AM25Ts per CR1000X, CR1000, or CR3000
Internal PRT Accuracy
  • ±0.2°C (-25° to +50°C)
  • ±0.4°C (-40° to +85°C)
Power 9.6 to 16 Vdc (under load), unregulated
Typical Relay Resistance 500 Ω
Maximum Switching Current 25 mA (Switching currents greater than 25 mA will damage the relays and render them unusable.)
CE Compliance Conforms to EN55022-1:1995 and EN50082-1:1992.
Operating Temperature Range -40° to +85°C
Operating Humidity Range 0 to 95% (non-condensing)
Dimensions 23.6 x 5.1 x 13.2 cm (9.3 x 2 x 5.2 in.)
Weight 0.9 kg (2.0 lb)

Typical Current Drain

Quiescent 0.5 mA
Active 1.0 mA

Enable Levels

Inactive < 0.9 V
Active 3.5 to 5 V

Clock

Levels Scan advance occurs on the falling edge of the clock pulse (from above 3.5 V to below 1.5 V)
Minimum ON Time 50 µs
Minimum OFF Time 60 μs

兼容性

Please note: The following shows notable compatibility information. It is not a comprehensive list of all compatible products.

数据采集器

Product Compatible Note
21X (retired)
CR10 (retired)
CR1000X
CR10X (retired)
CR200X (retired)
CR206X (retired)
CR211X (retired)
CR216X (retired)
CR23X (retired)
CR295X (retired)
CR300
CR3000 (retired)
CR310
CR350
CR500 (retired)
CR5000 (retired)
CR510 (retired)
CR6
CR800 (retired)
CR850 (retired)

固定设备

Product Compatible Note
ENC10/12
ENC10/12R
ENC12/14
ENC14/16
ENC16/18
ENC24/30
ENC24/30S

Additional Compatibility Information

Sensors

The AM25T is typically used with type T, E, J, or K thermocouples; different thermocouple types are also supported (depends on data logger model and operating system). The AM25T can also measure other sensors that have a low-level voltage output. However, the AM25T should NOT be used with resistive bridges or be configured with a voltage divider between the AM25T and the data logger. The AM16/32B multiplexer is available for these applications.

Software/Programming

The AM25T is controlled by the AM25T instruction in CRBasic. When using Edlog, data logger Instruction 134 is used with recently shipped versions of the data loggers; older data loggers can measure and control the AM25T with a series of data logger instructions.

Short Cut software (available free of charge from our website) supports simple programming and generates wiring diagrams for AM25T applications; older versions of Short Cut did not support multiplexers.

Enclosure Considerations

The AM25T operates in most field conditions but requires a non-condensing environment. Outdoor applications require a weather-resistant enclosure augmented by desiccant; a Campbell Scientific enclosure is recommended.

Our ENC12/14 enclosure can house up to two AM25Ts, a CR800, CR850, CR10X, CR1000, or CR3000, and a power supply. The ENC16/18 houses several AM25Ts, a CR800, CR850, CR10X, CR1000, CR3000, or CR5000, and a power supply.


常见问题解答

AM25T: 10

展开全部收起全部

  1. Bridge-type circuits (107/108 probes, PRTs, load cells, strain gages, and pressure transducers) should be used with the AM16/32(A or B) to preserve measurement accuracy and repeatability. Voltage signals (thermocouples, thermopiles, and high-level voltages) can be used with the AM25T multiplexer without any degradation to measurement accuracy or repeatability.

  2. The AM25T was designed specifically to interface to Campbell Scientific data loggers only, with no provisions to interface to third-party devices.

  3. The mechanical contact relays of the AM16/32B are subject to corrosion and pitting, which leads to increased relay resistance and greater variations of the resistance with each contact cycle.  Switched currents in excess of 30 mA degrade the relay contacts involved, rendering the channel unsuitable for further low-level analog measurements.  (If an AM16/32 relay has been used for currents greater than 30 mA, it is not suitable for low-level mV measurements.) The switching of higher level currents causes increased corrosion and pitting of the relays. The solid-state relays on the AM25T multiplexer are not subject to corrosion and pitting; therefore, they are more suitable for low-level mV signals.

  4. The number of switched lines and banks is different between the two multiplexers. The AM16/32B multiplexer has the operating option of running 16 banks of 4 lines each or of running 32 banks of 2 lines each. The AM25T multiplexer has only the one operating mode of 25 banks of 2 lines each. The 4x16 and 2x32 modes of the AM16/32B can offer more channels, convenience, and flexibility in applications than the 2x25-only mode of the AM25T multiplexer can. The 4x16 operation mode of the AM16/32B is a significant advantage for resistive bridge measurements to switch the current to the bridge circuits in addition to lines set up for the bridge output voltage. The 2x32 mode of the AM16/32B and the 2x25 mode of the AM25T multiplexer are commonly used for sensors that require no excitation (that is, voltages and thermocouples). In the 2x32 mode, the AM16/32B multiplexer has seven more channels than the AM25T offers.

  5. Programming the AM25T multiplexer might be considered more convenient because the newer data loggers have a built-in AM25T CRBasic instruction to handle both AM25T differential thermocouple measurements and differential voltage measurements.  There is no CRBasic built-in instruction for the AM16/32B multiplexer. However, the newer versions of the Short Cut program builder software have AM16/32B compatibility for a variety of different sensor types.

  6. The differences between the mechanical relays on the AM16/32B and the solid-state relays on the AM25T are noteworthy with regard to switching time, voltage and current levels, power consumption, and relay activation noise.

    • Solid-state relays switch faster than mechanical relays. The solid-state relays on the AM25T have a maximum activation time of less than 1 ms, whereas the slower AM16/32B mechanical relays have a maximum activation of 20 ms. This is an important aspect to consider in high sample rate applications of a large number of channels.
    • The mechanical relays on the AM16/32B multiplexer are rated for handling higher voltage and current levels than the solid-state relays on the AM25T.
    • The power consumption for the mechanical relays on the AM16/32B multiplexer is significantly greater than that of the solid-state relays on the AM25T.
    • The mechanical relays on the AM16/32B multiplexer make a distinct clicking sound when closing. In contrast, the solid-state relays on an AM25T are silent. The sound of mechanical relays may be annoying to humans or animals at the installation site. In some applications, the clicking sound of the relays can be a beneficial indicator that measurements are being performed.
  7. The AM25T multiplexer has a built-in PRT temperature bridge circuit for accurate thermocouple cold junction compensation. It also has heat stabilization features designed to minimize temperature gradients across the wiring panel. The AM25T incorporates a large amount of thermal mass in a central concentrated area around the wiring panel terminals. The wiring terminals on the AM25T are located close to each other and close to the heat stabilization mass. 

    On the AM16/32B multiplexer, the wiring panel terminals are spread out across a larger area and do not have the large thermal mass design around the terminals that the AM25T has. Part of the thermal mass includes a heat bar that runs under the wiring panel connectors of which the PRT reference element is coupled to. The PRT element is incorporated into a precision full bridge circuit and calibrated for accurate reference temperature readings. The AM16/32B multiplexer does not have a built-in reference temperature PRT and heat bar design. When using AM16/32B multiplexers for thermocouple measurements, an external reference temperature measurement will need to be provided. 

    Because of its built-in reference temperature circuit and thermal stabilization features, the AM25T multiplexer is more suitable for thermocouple measurements.

  8. The AM25T is typically used with thermocouples. It uses solid-state relays, which have a varying impedance from one closure to the next. This impedance is higher than the impedance in the mechanical relays used in the AM16/32-series multiplexer or the retired AM416 multiplexer. Bridge circuits (107/108 probes, PRTs, load cells, strain gages, and pressure transducers) should not be connected to the AM25T because of the varying and higher impedance values (compared to the AM16/32).

  9. The mechanical relays on the AM16/32B are subject to wear and thus have a limited lifetime. The minimum life rating of the AM16/32B relays is 107 closures. For a relay cycle interval of 1 second, the minimum lifetime is three years. The solid-state relays on an AM25T don't have this issue.

  10. The mechanical relays of the AM16/32B multiplexer are needed for switching excitation currents into resistive bridge measurement circuits. The solid-state relays of an AM25T multiplexer, in contrast, are not suitable for this. The switching relays on the AM16/32B multiplexer are mechanical and have an order of 0.1 ohm resistance. In contrast, the relays on the AM25T are solid state with an on resistance of approximately 500 ohm. The significant resistance of the solid-state relays is problematic for the precision excitation current needed for resistive bridge measurements.

案例研究

特拉华河: 桥梁监测
Intelligent Infrastructure Systems, a Pennoni company, was contracted to design and install an efficient structural-health......阅读更多
太空农场研究
Imagine the bored mind of a space traveler as he looks around the room he......阅读更多
Illinois: Research Roof Garden
The 385-acre Chicago Botanic Garden welcomes more than 750,000 visitors each year. Its new Daniel......阅读更多