标准机箱 / ENC10/12R
ENC10/12R 更深的机箱,宽 x 高为 10 x 12 英寸

概览

该型号机箱与ENC10/12 类似,但其机箱门更高,这允许了更高的外设安装在ENC10/12R内部。ENC10/12R 通常用于安装一个较小的数据采集器、供电电源和一个小型外设。还可以用于安装远距离的外设,例如扩展板。

优势与特点

  • 白色的抗紫外机箱反射了太阳辐射 — 减少了机箱内的温度梯度,不需要别的防辐射措施

图像

Backplate that is used inside the enclosure

技术说明

The ENC10/12R's backplate is prepunched with half-inch-on-center holes suitable for attaching a data logger, power supply, and a communications or measurement and control peripheral.

The ENC10/12R is shipped with the 7363 enclosure supply kit that consists of desiccant, a humidity indicator card, cable ties, wire tie tabs, putty, grommets, screws, and PVC coupling. Additionally, Campbell Scientific offers a CS210 Enclosure Humidity Sensor for monitoring relative humidity inside of the enclosure. (See Ordering Info on the web page.)

产品规格

Construction Fiberglass-reinforced polyester enclosure with door gasket, external grounding lug, stainless-steel hinge, and lockable hasps
Color White (Reflects solar radiation, reducing temperature gradients inside the enclosure without using a separate radiation shield.)
Enclosure Classification NEMA 4X (before being modified for cable entry, conduit, or ground lug)
Number of Cable-Entry Seals 1 medium, 2 small
Dimensions
  • 30.5 x 25.4 x 14 cm (12 x 10 x 5.5 in.) internal
  • 28.42 x 23.44 x 15.09 cm (11.19 x 9.23 x 5.94 in.) internal under the lid space
  • 34.06 x 29.03 x 16.76 cm (13.41 x 11.43 x 6.6 in.) external
Weight 4.1 kg (9 lb)

兼容性

Please note: The following shows notable compatibility information. It is not a comprehensive list of all compatible products.

数据采集器

Product Compatible Note
21X (retired)
CR10 (retired)
CR10X (retired)
CR200X (retired)
CR206X (retired)
CR211X (retired)
CR216X (retired)
CR23X (retired)
CR295X (retired)
CR300
CR3000 (retired) The ENC10/12R is compatible with the CR3000. Similar to the CR800/CR850 and CR1000, the CR3000 must be mounted vertically rather than horizontally. No space remains in the enclosure for additional peripherals.
CR350
CR500 (retired)
CR5000 (retired)
CR510 (retired)
CR6
CR800 (retired) Although the CR800 is compatible, this data logger can only fit inside the ENC10/12R if it is mounted vertically rather than horizontally.
CR850 (retired) Although the CR850 is compatible, this data logger can only fit inside the ENC10/12R if it is mounted vertically rather than horizontally.
CR9000 (retired)

测量与控制

Product Compatible Note
SDM-SIO4 (retired)

固定设备

Product Compatible Note
CM500 (retired)
CM505
CM510
CM515

Additional Compatibility Information

Peripherals

Retired peripherals that won’t fit in the same ENC10/12R enclosure as the data logger/power supply include the AVW4, AM416, COM100, CR10KD, DC1765, and RC35.


常见问题解答

ENC10/12R: 14

展开全部收起全部

  1. If you purchased a Stahlin enclosure from Campbell Scientific and it has a failed gasket, we can help you. We will need you to provide an image of the failed gasket, verify the size of your enclosure, and provide your contact information. We can then arrange to have a replacement gasket sent to you from Stahlin. For assistance, contact Technical Support at 435.227.9100.

  2. The terminals do not need to be replaced. Just sand or file the corrosion away, exposing clean copper, and the fittings will continue to be functional.
  3. Our fiberglass enclosures can withstand very cold locations, and their fiberglass/plastic construction is very resistant to corrosion.
  4. It depends on the device. Most devices have built-in mounting flanges, but some items require a separate mounting bracket.
  5. 是。Campbell Scientific 所销售的每一个防护机箱都含有一个亚光处理的背板,背板钻有按1 英寸间距分布的孔,匹配我们设备的安装用法兰,使得安装过程非常轻松便捷。
  6. The following information is applicable to many of Campbell Scientific’s standard enclosures and prewired enclosures.

    Note: The procedure below will not work for torn or damaged seals.

    To make a field repair to a loose gasket on an enclosure, first acquire an adhesive, such as standard Gorilla Glue, that is rated for use with polyurethane foam. The adhesive should be compatible with, and recommended for, use with polyurethane foam. Follow these steps:

    1. Pull the gasket away from the gasket channel, being careful not to tear the gasket. The gasket does not need to be removed completely. Rather, remove only those areas that have pulled loose on their own. To keep the gasket up out of the way, lay a small object (such as a toothpick, pen, or pencil) horizontally across the channel.
    2. Using an adhesive that is rated for use with polyurethane foam, apply a small bead of adhesive to the gasket channel. Because the adhesive’s only function is to keep the gasket in place, use it sparingly.
    3. Remove any objects that were holding the gasket out of the way.
    4. Carefully place the gasket in the gasket channel.
    5. Wait 1 to 3 hours for the adhesive to cure before closing the door.
  7. 是。在我们网站中的机箱页面下的订购栏中 (Ordering tab) 中,向下滚动找到备件区域 (Replacement Parts) ,那里列有用于该型号机箱的通用背板。
  8. 是。CD100 固定在机箱门上,支持所有的 CR1000KD 功能。通过 CD100,可以查看历史数据和实时数据,也能够不打开机箱门就可以输入指令。

    另外可用的显示器是 CD295CD294,它们仅能显露实时数据。

  9. 使用带细齿钻头的刮刨工具。孔锯 (开孔器) 也可以工作,但其边缘不如使用刮刨工具干净。