标准机箱 / ENC16/18
ENC16/18 机箱,宽 x 高为 16 x 18 英寸
结实的,多用途的
可容易而安全地安装Campbell的产品
气象 应用支持 水资源 应用支持 能源 应用支持 湍流通量 应用支持 基础结构/工业设施 应用支持 土壤 应用支持

概览

ENC16/18为耐候机箱,宽16英寸,高18英寸。它是标准机箱系列里最大的一种,可容纳一个数据采集器,一个供电电源和至少一个外设。建议ENC16/18机箱用于需要将多个通讯或测量控制模块安放在同一个机箱内的应用。

请注意,机箱不包括接地线。

优势与特点

  • 耐候,保护设备
  • Two backplate options available so that Campbell Scientific components mount easily and securely (Differs from our other enclosures because you can choose between two backplates.)
  • 白色的抗紫外机箱反射了太阳辐射 — 减少了机箱内的温度梯度,不需要别的防辐射措施

图像

技术说明

ENC16/18机箱内的底板以1/2英寸等间距的网格预先打好了孔,适合安装数据采集器、供电电源、以及通讯或测量控制外设。

ENC16/18发运时带有7363机箱配件包,含有干燥剂、湿度指示卡片、绑扎线、固定线缆粘块、灰泥、护线套、螺丝、PVC耦合连接。另外,Campbell Scientific供应CS210机箱内湿度传感器用于监测机箱内的相对湿度(见订货信息)。

产品规格

Color White (Reflects solar radiation, reducing temperature gradients inside the enclosure without using a separate radiation shield.)
Construction Fiberglass-reinforced polyester enclosure with door gasket, external grounding lug, stainless-steel hinge, and lockable hasps
Enclosure Classification NEMA 4X (before being modified for cable entry)
Number of Cable-Entry Seals 2 large, 2 medium, 2 small
Dimensions
  • 45.7 x 40.6 x 22.9 cm (18 x 16 x 9 in.) internal
  • 43.82 x 38.74 x 25.22 cm (17.25 x 15.25 x 9.93 in.) internal under the lid space
  • 49.53 x 44.4 x 26.98 cm (19.5 x 17.48 x 10.62 in.) external
Weight 7.7 kg (17 lb)

兼容性

Please note: The following shows notable compatibility information. It is not a comprehensive list of all compatible products.

数据采集器

Product Compatible Note
21X (retired)
CR10X (retired)
CR200X (retired)
CR206X (retired)
CR211X (retired)
CR216X (retired)
CR23X (retired)
CR295X (retired)
CR300 (retired)
CR3000 (retired)
CR350
CR500 (retired)
CR5000 (retired)
CR510 (retired)
CR6
CR800 (retired)
CR850 (retired)
CR9000 (retired)

固定设备

Product Compatible Note
CM500 (retired)
CM505
CM510
CM515

Additional Compatibility Information

The -VC cable opening option is required to fit a BP84 84-Ahr power supply in the ENC16/18 (see Ordering Info).


常见问题解答

ENC16/18: 18

展开全部收起全部

  1. Yes. Use a standard electrical box and outlet.
  2. The ENC16/18 weighs 17 lb. Its internal dimensions are 16 x 18 x 9 in.
  3. Most likely, yes. The data logger is protected against electrical noise, and 60 Hz filtering can be selected in many sensor measurements to filter out the effects of 60 Hz noise.

  4. If you purchased a Stahlin enclosure from Campbell Scientific and it has a failed gasket, we can help you. We will need you to provide an image of the failed gasket, verify the size of your enclosure, and provide your contact information. We can then arrange to have a replacement gasket sent to you from Stahlin. For assistance, contact Technical Support at 435.227.9100.

  5. The terminals do not need to be replaced. Just sand or file the corrosion away, exposing clean copper, and the fittings will continue to be functional.
  6. Our fiberglass enclosures can withstand very cold locations, and their fiberglass/plastic construction is very resistant to corrosion.
  7. It depends on the device. Most devices have built-in mounting flanges, but some items require a separate mounting bracket.
  8. The following information is applicable to many of Campbell Scientific’s standard enclosures and prewired enclosures.

    Note: The procedure below will not work for torn or damaged seals.

    To make a field repair to a loose gasket on an enclosure, first acquire an adhesive, such as standard Gorilla Glue, that is rated for use with polyurethane foam. The adhesive should be compatible with, and recommended for, use with polyurethane foam. Follow these steps:

    1. Pull the gasket away from the gasket channel, being careful not to tear the gasket. The gasket does not need to be removed completely. Rather, remove only those areas that have pulled loose on their own. To keep the gasket up out of the way, lay a small object (such as a toothpick, pen, or pencil) horizontally across the channel.
    2. Using an adhesive that is rated for use with polyurethane foam, apply a small bead of adhesive to the gasket channel. Because the adhesive’s only function is to keep the gasket in place, use it sparingly.
    3. Remove any objects that were holding the gasket out of the way.
    4. Carefully place the gasket in the gasket channel.
    5. Wait 1 to 3 hours for the adhesive to cure before closing the door.