概览

41005-5A 自然通风的10-页防辐射罩,百叶窗结构允许空气自由通过遮荫罩,确保探头最为接近环境温度。白色遮荫罩可反射太阳辐射。

优势与特点

  • Naturally shades and protects the sensor

技术说明

The 41003-5A 10-Plate Gill Radiation Shield is typically used with an LW110 to house its HC2S3 Temperature and RH probe; the hex plug required to mount the HC2S3 in the shield is shipped with the sensor.

The 41003-5A can also house a 43347, 107, 108, 109, or HMP60 probe. The HMP45C and several other retired sensors are also compatible. Refer to the Compatibility tab for the hardware required to mount the above sensors in the shield.

产品规格

Construction UV-stabilized white thermoplastic plates, aluminum mounting bracket
Plate Diameter 11.9 cm (4.7 in.)
Height 20.3 cm (8.0 in.)
Weight 590 g (1.3 lb)

兼容性

Please note: The following shows notable compatibility information. It is not a comprehensive list of all compatible products.

传感器

Product Compatible Note
107 The 41322 adapter is required to install a 107 probe.
108 The 41322 adapter is required to install a 108 probe.
109 The 41322 adapter is required to install a 109 probe.
43347-L The 27251 hex plug is required to secure the 43347 RTD into the radiation shield's base.
CS215-L (retired)
CS500-L (retired) For the CS500, the 41322 adapter can be used to mount the sensor in the lower part of the shield. Alternatively, a 41381 extension tube and the 6637 hex plug can be used to mount the CS500 in a higher part of the shield; this configuration also requires the #18278 cable.
HC2S3-L (retired) The 27731 hex plug is required to mount the HC2S3 in the 41003-5A.
HMP155A-L
HMP35A (retired) The 27251 hex plug is required to mount an HMP35A in the 41003-5A.
HMP35C-L (retired) The 27251 hex plug is required to mount an HMP35C in the 41003-5A.
HMP45C-L (retired) The 27251 hex plug is required to mount an HMP45C in the 41003-5A.
HMP50-L (retired) For the HMP50, the 41322 adapter can be used to mount the sensor in the lower part of the shield. Alternatively, a 41381 extension tube and the 6637 hex plug can be used to mount the HMP50 in a higher part of the shield; this configuration also requires the #18278 cable.
HMP60-L For the HMP60, the 41322 adapter can be used to mount the sensor in the lower part of the shield. Alternatively, a 41381 extension tube and the 6637 hex plug can be used to mount the HMP60 in a higher part of the shield; this configuration also requires the #18278 cable.

Additional Compatibility Information

The 41003-5A attaches to a CM500-series pole or a user-supplied 2 in. IPS pole.

常见问题解答

41003-5A: 1

  1. To measure ambient temperature and relative humidity (RH), mount the HC2S3-L probe inside a 41003-5 or 41003-5A 10-Plate Radiation Shield. The 27731 hex plug is shipped with the HC2S3-L so that it can be used with older 10-plate radiation shield models. The 6-plate radiation shield (pn 41303-5A) cannot be used with the HC2S3-L.


文章和新闻发布

列在

Common Accessory for the following products: