The 41003-5A 10-Plate Gill Radiation Shield is typically used with an LW110 to house its HC2S3 Temperature and RH probe; the hex plug required to mount the HC2S3 in the shield is shipped with the sensor.
The 41003-5A can also house a 43347, 107, 108, 109, or HMP60 probe. The HMP45C and several other retired sensors are also compatible. Refer to the Compatibility tab for the hardware required to mount the above sensors in the shield.
Construction | UV-stabilized white thermoplastic plates, aluminum mounting bracket |
Plate Diameter | 11.9 cm (4.7 in.) |
Height | 20.3 cm (8.0 in.) |
Weight | 590 g (1.3 lb) |
Please note: The following shows notable compatibility information. It is not a comprehensive list of all compatible products.
Product | Compatible | Note |
---|---|---|
107 | The 41322 adapter is required to install a 107 probe. | |
108 | The 41322 adapter is required to install a 108 probe. | |
109 | The 41322 adapter is required to install a 109 probe. | |
43347-L | The 27251 hex plug is required to secure the 43347 RTD into the radiation shield's base. | |
CS215-L (retired) | ||
CS500-L (retired) | For the CS500, the 41322 adapter can be used to mount the sensor in the lower part of the shield. Alternatively, a 41381 extension tube and the 6637 hex plug can be used to mount the CS500 in a higher part of the shield; this configuration also requires the #18278 cable. | |
HC2S3-L (retired) | The 27731 hex plug is required to mount the HC2S3 in the 41003-5A. | |
HMP155A-L | ||
HMP35A (retired) | The 27251 hex plug is required to mount an HMP35A in the 41003-5A. | |
HMP35C-L (retired) | The 27251 hex plug is required to mount an HMP35C in the 41003-5A. | |
HMP45C-L (retired) | The 27251 hex plug is required to mount an HMP45C in the 41003-5A. | |
HMP50-L (retired) | For the HMP50, the 41322 adapter can be used to mount the sensor in the lower part of the shield. Alternatively, a 41381 extension tube and the 6637 hex plug can be used to mount the HMP50 in a higher part of the shield; this configuration also requires the #18278 cable. | |
HMP60-L | For the HMP60, the 41322 adapter can be used to mount the sensor in the lower part of the shield. Alternatively, a 41381 extension tube and the 6637 hex plug can be used to mount the HMP60 in a higher part of the shield; this configuration also requires the #18278 cable. |
The 41003-5A attaches to a CM500-series pole or a user-supplied 2 in. IPS pole.
41003-5A: 1
To measure ambient temperature and relative humidity (RH), mount the HC2S3-L probe inside a 41003-5 or 41003-5A 10-Plate Radiation Shield. The 27731 hex plug is shipped with the HC2S3-L so that it can be used with older 10-plate radiation shield models. The 6-plate radiation shield (pn 41303-5A) cannot be used with the HC2S3-L.