41003-5 自然通风的10-页防辐射罩,带有百叶窗,允许空气自由通过遮荫罩,确保探头最为接近环境温度。白色遮荫罩可反射太阳辐射。
41003-5 10页 Gill防辐射罩适用于HC2S3或EE181-L温湿度探头。
41003-5 也适用于43347, 107, 108, 109或 HMP60探头。HMP45C 和其它一些停产的传感器。请参阅以上传感器的硬件兼容性要求。
41003-5 包括一个2英寸的带有塑料三角槽板的U型螺栓。U型螺栓安装在支架侧面的孔上,用于连接桅杆和垂直杆。也可安装在支架底部的孔上,用于连接横臂。
2005年6月,41003-5 10页防辐射罩代替 41002 12页Gill防辐射罩。41003-5最大的改进之处在于可以安装在任意一种垂直杆或横臂管上。停产的41002仅能安装在垂直杆上。 |
Construction | UV-stabilized white thermoplastic plates, aluminum mounting bracket, white powder-coated stainless-steel U-bolt clamp |
Plate Diameter | 11.9 cm (4.7 in.) |
Height | 20.3 cm (8.0 in.) |
Weight | 590 g (1.3 lb) |
Please note: The following shows notable compatibility information. It is not a comprehensive list of all compatible products.
Product | Compatible | Note |
---|---|---|
107 | The 41322 adapter is required to install a 107 probe. | |
108 | The 41322 adapter is required to install a 108 probe. | |
109 | The 41322 adapter is required to install a 109 probe. | |
43347-L | The 27251 hex plug is required to secure the 43347 RTD into the radiation shield's base. | |
CS215-L (retired) | ||
CS500-L (retired) | For the CS500, the 41322 adapter can be used to mount the sensor in the lower part of the shield. Alternatively, a 41381 extension tube and the 6637 hex plug can be used to mount the CS500 in a higher part of the shield; this configuration also requires the #18278 cable. | |
EE181-L | The 15823 hex plug is required to mount the EE181-L in the 41003-5. | |
HC2S3-L (retired) | The 27731 hex plug is required to mount the HC2S3 in the 41003-5. | |
HMP155A-L | ||
HMP35A (retired) | The 15823 hex plug is required to mount an HMP35A in the 41003-5. At one time, this hex plug was shipped with the radiation shield but it no longer is. | |
HMP35C-L (retired) | The 15823 hex plug is required to mount an HMP35C in the 41003-5. At one time, this hex plug was shipped with the radiation shield but it no longer is. | |
HMP45C-L (retired) | The 15823 hex plug is required to mount an HMP45C in the 41003-5. At one time, this hex plug was shipped with the radiation shield but it no longer is. | |
HMP50-L (retired) | For the HMP50, the 41322 adapter can be used to mount the sensor in the lower part of the shield. Alternatively, a 41381 extension tube and the 6637 hex plug can be used to mount the HMP50 in a higher part of the shield; this configuration also requires the #18278 cable. | |
HMP60-L | For the HMP60, the 41322 adapter can be used to mount the sensor in the lower part of the shield. Alternatively, a 41381 extension tube and the 6637 hex plug can be used to mount the HMP60 in a higher part of the shield; this configuration also requires the #18278 cable. | |
HygroVue 10 | Compatible with the use of the 6637 Hex Adapter Plug. |
The 41003-5 attaches to a crossarm, mast, or user-supplied pipe with a 1.0 to 2.1 in. OD.
41003-5: 2
To measure ambient temperature and relative humidity (RH), mount the HC2S3-L probe inside a 41003-5 or 41003-5A 10-Plate Radiation Shield. The 27731 hex plug is shipped with the HC2S3-L so that it can be used with older 10-plate radiation shield models. The 6-plate radiation shield (pn 41303-5A) cannot be used with the HC2S3-L.
No. The HMP155A-L requires the 41005-5 14-Plate Solar Radiation Shield.