41003-5 10-页防辐射罩
提供更精确的测量结果
可遮荫并保护传感器
气象 应用支持 水资源 应用支持 能源 应用支持 湍流通量 应用支持 基础结构/工业设施 应用支持 土壤 应用支持

概览

41003-5 自然通风的10-页防辐射罩,带有百叶窗,允许空气自由通过遮荫罩,确保探头最为接近环境温度。白色遮荫罩可反射太阳辐射。

优势与特点

  • Naturally shades and protects the sensor

图像

技术说明

41003-5 10页 Gill防辐射罩适用于HC2S3或EE181-L温湿度探头。

41003-5 也适用于43347, 107, 108, 109或 HMP60探头。HMP45C 和其它一些停产的传感器。请参阅以上传感器的硬件兼容性要求。

41003-5 包括一个2英寸的带有塑料三角槽板的U型螺栓。U型螺栓安装在支架侧面的孔上,用于连接桅杆和垂直杆。也可安装在支架底部的孔上,用于连接横臂。

2005年6月,41003-5 10页防辐射罩代替 41002 12页Gill防辐射罩。41003-5最大的改进之处在于可以安装在任意一种垂直杆或横臂管上。停产的41002仅能安装在垂直杆上。

产品规格

Construction UV-stabilized white thermoplastic plates, aluminum mounting bracket, white powder-coated stainless-steel U-bolt clamp
Plate Diameter 11.9 cm (4.7 in.)
Height 20.3 cm (8.0 in.)
Weight 590 g (1.3 lb)

兼容性

Please note: The following shows notable compatibility information. It is not a comprehensive list of all compatible products.

传感器

Product Compatible Note
107 The 41322 adapter is required to install a 107 probe.
108 The 41322 adapter is required to install a 108 probe.
109 The 41322 adapter is required to install a 109 probe.
43347-L The 27251 hex plug is required to secure the 43347 RTD into the radiation shield's base.
CS215-L (retired)
CS500-L (retired) For the CS500, the 41322 adapter can be used to mount the sensor in the lower part of the shield. Alternatively, a 41381 extension tube and the 6637 hex plug can be used to mount the CS500 in a higher part of the shield; this configuration also requires the #18278 cable.
EE181-L The 15823 hex plug is required to mount the EE181-L in the 41003-5.
HC2S3-L (retired) The 27731 hex plug is required to mount the HC2S3 in the 41003-5.
HMP155A-L
HMP35A (retired) The 15823 hex plug is required to mount an HMP35A in the 41003-5. At one time, this hex plug was shipped with the radiation shield but it no longer is.
HMP35C-L (retired) The 15823 hex plug is required to mount an HMP35C in the 41003-5. At one time, this hex plug was shipped with the radiation shield but it no longer is.
HMP45C-L (retired) The 15823 hex plug is required to mount an HMP45C in the 41003-5. At one time, this hex plug was shipped with the radiation shield but it no longer is.
HMP50-L (retired) For the HMP50, the 41322 adapter can be used to mount the sensor in the lower part of the shield. Alternatively, a 41381 extension tube and the 6637 hex plug can be used to mount the HMP50 in a higher part of the shield; this configuration also requires the #18278 cable.
HMP60-L For the HMP60, the 41322 adapter can be used to mount the sensor in the lower part of the shield. Alternatively, a 41381 extension tube and the 6637 hex plug can be used to mount the HMP60 in a higher part of the shield; this configuration also requires the #18278 cable.
HygroVue 10 Compatible with the use of the 6637 Hex Adapter Plug.

Additional Compatibility Information

The 41003-5 attaches to a crossarm, mast, or user-supplied pipe with a 1.0 to 2.1 in. OD.

常见问题解答

41003-5: 2

  1. To measure ambient temperature and relative humidity (RH), mount the HC2S3-L probe inside a 41003-5 or 41003-5A 10-Plate Radiation Shield. The 27731 hex plug is shipped with the HC2S3-L so that it can be used with older 10-plate radiation shield models. The 6-plate radiation shield (pn 41303-5A) cannot be used with the HC2S3-L.