概览

HC2S3是一款坚实耐用的精确的空气温度/相对湿度探头,适用于长期的无人值守的应用。探头使用高级的电容传感器测量相对湿度。探头所包括的过滤器可保护传感器免受灰尘和颗粒的污染,具有较好的性能和可靠性。

优势与特点

  • 特别适合长期的无人值守的应用
  • 精确而且耐用
  • 兼容所有的Campbell Scientific数据采集器 。

图像

技术说明

HC2S3 到货时配有聚乙烯过滤器,保护传感器免受细小灰尘和颗粒物的污染,并最小化水汽吸收和滞留。或者,也可使用Teflon过滤器用于海洋环境,当使用Teflon 过滤器时响应时间变慢。

产品规格

Electronics Operating Limits -40° to +100°C
Storage Temperature Range -50° to +100°C
Current Consumption
  • < 4.3 mA (@ 5 Vdc)
  • < 2.0 mA (@ 12 Vdc)
Supply Voltage 5 to 24 Vdc
Startup Time 1.5 s (typical)
The startup time is a Rotronics specification. For programming, Campbell Scientific recommends a 2 s delay at 60°C, a 3 s delay at 0°C, and a 4 s delay at -40°C.
Maximum Startup Current < 50 mA (for 2 μs)
Analog Outputs
  • ±3 mV (maximum) offset at 0 V.
  • < ±1 mV (0.1°C, 0.1% R. H.) deviation for digital signal
Diameter 15 mm (0.6 in.)
Length
  • 85 mm (3.3 in.) without connector
  • 183 mm (7.25 in.) with connector
Weight 10 g (0.35 oz)

Air Temperature

Measurement Range -40° to +60°C (default)
Air temperature measurement ranges from -50° to +100°C are possible; contact Campbell Scientific for more information.
Output Signal Range 0 to 1 V
Long-Term Stability < 0.1°C/year
Sensor Time Constant - Standard PE Filter ≤ 22 s (63% step change [1 m/s air flow at sensor])
Sensor Time Constant - Optional Teflon Filter ≤ 30 s (Typical 4 s, 63% of a step change [1 m/s air flow at sensor])
Temperature Accuracy Refer to graph in probe manual.

Relative Humidity

Measurement Range 0 to 100% RH (non-condensing)
Output Signal Range 0 to 1 Vdc
Long-Term Stability < 1% RH per year
Accuracy ±0.8% RH with standard configuration settings (at 23°C)
Sensor Time Constant - Standard PE Filter ≤ 22 s (63% of a 35 to 80% RH step change [1 m/s air flow at sensor])
Sensor Time Constant - Optional Teflon Filter ≤ 30 s (Typical 10 s, 63% of a 35 to 80% RH step change [1 m/s air flow at sensor])
RH Accuracy over Temperature Refer to graph in probe manual.

兼容性

Please note: The following shows notable compatibility information. It is not a comprehensive list of all compatible products.

数据采集器

Product Compatible Note
21X (retired)
CR10 (retired)
CR1000X (retired)
CR10X (retired)
CR200X (retired)
CR206X (retired)
CR211X (retired)
CR216X (retired)
CR23X (retired)
CR295X (retired)
CR3000 (retired)
CR500 (retired)
CR5000 (retired)
CR510 (retired)
CR800 (retired)
CR850 (retired)
CR9000 (retired)

Additional Compatibility Information

Mounting

The HC2S3 should be housed in a 41003-5 10-plate naturally-aspirated solar radiation shield. This radiation shield mounts to a tripod or tower mast, crossarm, or user-supplied pole.


常见问题解答

HC2S3-L: 5

展开全部收起全部

  1. It is possible that an older version of Short Cut is being used. Download the latest version of Short Cut.

  2. Campbell Scientific offers two filter tips:

    • The HC2S3-L comes with a polyethylene filter that provides protection against fine dust particles, doesn't absorb or retain water, and offers a good response time.
    • A Teflon filter can be ordered separately (pn 27755HC2S3 Replacement Teflon Filter). This filter has a smaller pore size (10 micron) that provides good protection against fine dust particles and salt (marine environments), but it has a slightly slower response time than the polyethylene filter.
  3. The sensor should not be cleaned with water. If the sensor is dirty, the filter should be changed or cleaned more frequently. A dirty filter can be cleaned with distilled water.

  4. To measure ambient temperature and relative humidity (RH), mount the HC2S3-L probe inside a 41003-5 or 41003-5A 10-Plate Radiation Shield. The 27731 hex plug is shipped with the HC2S3-L so that it can be used with older 10-plate radiation shield models. The 6-plate radiation shield (pn 41303-5A) cannot be used with the HC2S3-L.

  5. Note the difference between calibration and a field check. Calibration cannot be done in the field, as it requires an experienced technician and specialized equipment.

    Field checks of measurements can be done to determine if the data make sense with the real-world conditions. Follow these steps to field check a sensor:

    1. Find a second sensor of the same type as the installed sensor whose data is in question. The second sensor will be used as a benchmark sensor and should be known to be accurate or recently calibrated.
    2. At the site, take readings using both sensors under the same conditions. The best practice is to measure both sensors side-by-side at the same time. Note that the sensors will never have the exact same measurement.
    3. Depending on the sensor model, if the difference in the readings of the installed and benchmark sensors is greater than the sum of the accuracies for both sensors, either return the installed sensor to Campbell Scientific for calibration or replace the appropriate chip.
      • The 107, 108, 109, 110PV-L, and BlackGlobe-L temperature sensors can be calibrated.
      • The HC2S3-L and HMP155A-L temperature and relative humidity sensors can be calibrated.
      • The CS215-L has a replaceable chip for temperature and relative humidity. For more information, refer to the “Maintenance and Calibration” section of the CS215 instruction manual.
      • The HMP60-L has a replaceable chip for relative humidity only. For more information, refer to the “Maintenance” section of the HMP60 instruction manual.