停产的 ›
这个产品是无效的.
A6REL-12 继电器驱动器
Services Available
Repair No
Free Support Yes

概览

A6REL-12 包括6个内部继电器,允许 Campbell Scientific 的数据采集器控制12个外部交流电源或直流电源设备。可以手动或使用数据采集器来控制每个继电器。

优势与特点

  • UL/CUL认证的产品

图像

技术说明

A6REL-12 的内部继电器为单刀双掷。每6个继电器有一个三位扳钮开关,可手动控制"on" 和"off"或调整至"auto"由数据采集器控制。在"on"的位置,共同点和常开触点是短路的,"auto"位置,继电器有数据采集器控制端口控制。

序列号大于1445的A6REL-12已通过UL(美国保险商试验所)检验。

产品规格

Function Controls up to 12 external ac or dc devices.
Number of Channels 6
Operating Voltage 12 Vdc nominal (8.4 to 24 Vdc)
Current Drain at 12 Vdc
  • 6 µA quiescent
  • 30 mA per active LED (switch ON or AUTO active)
Toggle Switch ON/OFF manual override; AUTO for data logger control
Relays dual single pole double throw, break before make
Contact Material Gold-clad silver
Coil Resistance 720 Ω ±10%
Contact Ratings
  • 2 A (@ 30 Vdc)
  • 0.6 A (@ 125 Vac)
Release/Actuation Time ~3 ms
Operating Temperature -40° to +70°C
Standards
  • Underwriters Laboratories (UL) listed product (E162021)
  • Canadian Underwriters Laboratories (CUL) listed product (5Z21)
Dimensions 22.4 x 13.9 x 4.1 cm (8.8 x 5.5 x 1.6 in.) including switches and mounts
Weight 635 g (1.4 lb)

Expected Life (contact closures)

Mechanical 108
Electrical
  • 5x105 (2 A at 30 Vdc)
  • 2x106 (1 A at 30 Vdc )

兼容性

Please note: The following shows notable compatibility information. It is not a comprehensive list of all compatible products.

数据采集器

Product Compatible Note
21X (retired)
CR10 (retired)
CR10X (retired)
CR200X (retired)
CR206X (retired)
CR211X (retired)
CR216X (retired)
CR23X (retired)
CR295X (retired)
CR3000 (retired)
CR500 (retired) The CR500 has only one control port capable of providing a control signal.
CR5000 (retired)
CR510 (retired) The CR510 has only one control port capable of providing a control signal.
CR800 (retired) The CR800 has only four control ports capable of providing a control signal.
CR850 (retired) The CR850 has only four control ports capable of providing a control signal.
CR9000 (retired)

固定设备

Product Compatible Note
ENC10/12
ENC10/12R
ENC12/14
ENC14/16
ENC16/18
ENC24/30
ENC24/30S

Additional Compatibility Information

Data Logger Considerations

Each of the six relays is controlled by a data logger control port.

Cables

Cable(s) Used Number of Relays Controlled
One CABLE3CBL-L 1
One CABLE4CBL-L 2
One CABLE5CBL-L 3
Two CABLE3CBL-L 4
One CABLE3CBL-L and
one CABLE4CBL-L
5
Two CABLE4CBL-L 6

Power Considerations

The A6REL-12 consumes 30 mA per active LED. The A6REL-12 may be powered by the data logger power supply (see manual for considerations with 21X) or a separate 8.4 to 24 Vdc battery. The A6REL-12 must be powered by a Class 2 device (Campbell Scientific power supplies conform to this requirement).

Enclosure Considerations

The A6REL-12 requires a non-condensing environment; a Campbell Scientific enclosure is recommended. A6REL-12's with serial numbers 1445 and higher include mounting flanges with keyhole slots that attach to the backplate of an enclosure. Grommets and screws are provided.

A6REL-12s with serial numbers 1444 and lower require the 6281 bracket kit for attachment to the backplate of Campbell enclosures.


常见问题解答

A6REL-12: 1

  1. The following relay devices can be used with the CR800 and the CR850:

    • 7321
    • A6REL-12*
    • A21REL-12
    • LR4
    • SDM-CD8S
    • SDM-CD16AC
    • SDM-CD16ACA
    • SDM-CD16S

    The CR800 and the CR850 can also be used with a wide variety of third-party relay devices.

    *Because the CR800 and the CR850 only have four digital ports, they do not have the ability to switch all six of the relays on the A6REL-12.