COM320 语音电话modem
语音合成
让您的数据采集器可以说话
气象 应用支持 水资源 应用支持 能源 应用支持 湍流通量 应用支持 基础结构/工业设施 应用支持 土壤 应用支持

概览

COM320是一种语音合成modem,向CR800, CR850, CR1000, 或 CR3000 数据采集器添加了语音播报功能。该功能允许用户呼叫数据采集器站点提供关于实时数据或历史数据的语音概要。COM320还可以作为标准modem使用。

优势与特点

  • Allows anyone to call a COM320-equipped site from any phone (including cellular) to receive a verbal report of current site conditions.
  • Enables the data logger to call you and recite a verbal warning if specified conditions occur.
  • Reports specific conditions or allows selection of information by pressing numbers on a touch-tone telephone
  • Uses voice strings created with CRBasic code
  • Operates over a wide temperature range
  • Supports communication rates up to 115.2 kbps between modem and data logger
  • Includes a speaker that aids troubleshooting in the field

图像


3D/CAD 文件:

技术说明

>COM320含有1个CS I/O端口,1个电源端子,1个接线端子,和1个RJ-11C插孔。数据采集器通过SC12 或 SC12R-6线缆连接到COM320的CS I/O端口。RJ-11C插孔用于连接带有浪涌保护的固话线。此外,接线端子(GND, RING, TIP)也可用于将COM320通过浪涌保护器连接到固话线。

COM320设有标准单词列表(见右侧文档)。Campbell Scientific可能最终会往标准单词列表中添加更多的单词。在某些指定的应用中,用户要求的单词也可以包括进来;请向厂家咨询详细信息。使用CRBasic代码来对COM320的语法进行编程。

要求的设备

关于要求设备的更详细信息在设置标签下。

  • 电话
  • 模拟电话线路
  • 如果电话公司没有安装浪涌保护器,在数据采集器站点安装一个。
  • COM320语音合成modem(包括SC12线缆)
  • CR800, CR850, CR1000, 或 CR3000 数据采集器
  • 耐候机箱
  • 电源

还需要 数据采集器 - PC通讯,在PC端,运行PC400、LoggerNet或RTDAQ数据采集器支持软件的台式机或笔记本电脑,7026串口线或等效的modem线缆,以及用户提供的兼容Hayes标准的modem。

产品规格

Transmission Distance or Area Worldwide
Operation 1200 to 115200 baud digital communications over phone lines
Operation
  • Generated voice messaging for incoming or outgoing calling
  • Touch-tone selection voice responses
Operating Temperature Range -25° to +50°C (standard)
Operating Voltage 12 Vdc
Current Drain
  • ~100 μA (quiescent)
  • ~35 mA (active)
Communication Rate 9600, 38400, 57600, 115200 bps (between data logger and COM320, and selected by user)
Data Logger Interface CS I/O, SDC9 (not changeable)
Standards V.92, K56Flex, V.90, V.34, V.32bis, V32, V23, V22bis, V22, V.21, B212, B103
Registration
  • FCC US 3A4M508BSM2-T-W
  • IC 2377 A-SM2TW
  • TBR21
Service Requirements If not available at the site, phone lines must be installed.
Dimensions 16.5 x 2.5 x 6.6 cm (6.5 x 1.0 x 2.6 in.)
Weight 0.16 kg (0.35 lb)

兼容性

Please note: The following shows notable compatibility information. It is not a comprehensive list of all compatible products.

数据采集器

Product Compatible Note
CR1000X
CR200X (retired)
CR206X (retired)
CR211X (retired)
CR216X (retired)
CR295X (retired)
CR300
CR3000 (retired) OS version 9 or higher
CR310
CR350
CR5000 (retired)
CR6
CR800 (retired) OS version 7 or higher
CR850 (retired) OS version 7 or higher

固定设备

Product Compatible Note
ENC10/12
ENC10/12R
ENC12/14
ENC14/16
ENC16/18

Additional Compatibility Information

Programming

The COM320’s “sentences” are programmed using CRBasic code, which is included in PC400 and LoggerNet software. Both of these software packages support automated error-checking or user-initiated contacts.

Phone, Phone Lines, and Surge Protection

The COM320 must connect to an analog phone line. Some office environment PBX phone lines are digital and don’t interface to this analog modem. Of course, any phone may be used to call in to or receive callbacks from the COM320. A touch-tone phone is necessary for input or to navigate through the COM320’s menu system.

Typically, a length of phone line is run from the telephone company's junction box to the COM320s surge protector, and then to the Ground, Tip, and Ring terminals on the COM320. Alternately, if adequate surge protection is provided by the telephone company and the junction box supports it, a length of telephone wire with RJ11C connectors (#2365) can be run directly from the junction box to the socket on the COM320.

If the local telephone company does not provide surge protection, either the 6362 or 4330 surge protector should be used. See "Ordering Info" tab for more information.

Enclosure Considerations

The COM320 requires a desiccated, non-condensing environment; a Campbell Scientific enclosure is recommended. Grommets and screws are provided to attach the COM320 to the backplate of our enclosures.

下载

COM320 Firmware v.4.0 (621 KB) 28-01-2010

Execution of this download installs the COM320 Operating System on your computer.  

Note: The Device Configuration Utility is used to upload the included operating system to the datalogger.  Requires a USB cable.


COM320 USB Driver () 01-01-2014

Windows USB driver for the COM320 are distributed with the Device Configuration Utililty. In the Device Configuration Utility, click on the link "install the device driver for the COM320" in the main body of text for the COM320.

Note: Device Configuration Utility 2.08 or newer is required to install drives and configure the COM320.

 

COM310 Examples (5 KB) 22-04-2008

CR1000 CRBasic program examples showing COM310 data callback and voice support.

常见问题解答

COM320: 3

展开全部收起全部

  1. No; however, special words or phrases using a real person’s voice can be created for the COM320. Contact Campbell Scientific for a cost estimate for this service.

  2. Yes. By configuring the NL120 as a CSDC device, both the NL120 and COM320 can share the same CS I/O port. The CR1000 and CR3000 are capable of multi-threading, so the NL120 and COM320 can run in parallel. For more information, refer to the NL120 Ethernet Module Instruction Manual.

  3. No. Any communications device can be used to call out by the newer data loggers (except the CR200X-series), but the type of communications device used determines what type of information can be sent. The COM320 can be used to call out with a voice or to send data to LoggerNet

案例研究

Panama Canal: Upgraded Flood Warning System
The Panama Canal was using an outdated water-level system until the Panama Canal Authorities (ACP)......阅读更多
阿肯色州:洪水预警
Hot Springs, Arkansas, is a history-rich city located adjacent to Hot Springs National Park. The......阅读更多

文章和新闻发布