AVW206 无线振弦式接口包括一个内部的910-918 MHz 的射频电台用于无线通讯。内置美国和加拿大电台频率范围。该接口允许我们的数据采集器测量无线振弦式应变计,压力传感器,压强计,斜度仪,压式传感器等。这些传感器精确、耐用并且稳定,被广泛应用于建筑、水文和地理地质等方面。
AVW206 利用创新的频谱插值法测量传感器的谐振频率。运用这种方法,模块激活弦震传感器,测量响应时间,傅里叶变换情况,在2秒钟内以优于0.001 Hz&mdash的分辨率返回测量结果。频谱分析可以从频率组成的噪声中将信号区分出来,这种方法帮助改进抵抗噪声的能力。
AVW206 模块也提供了许多自检诊断,如振动元件信号强度、信噪比、振动元件信号衰减率,和不正确的信号响应。这些诊断可以在后台运行,为每个传感器的情况不断地给出反馈。
AVW206 通常通过与数据采集器连接的RF401(A)射频电台进行数据传输。AVW206也可直接与数据采集器连接。
-NOTE- | Electrical specifications are valid over a -25° to +50°C range unless otherwise specified. Non-condensing environment required. |
Internal Radio Frequency Range | 910 to 918 MHz |
Radio Power |
250 mW Older AVW206 modules (serial # < 11224) have 100 mW radios. |
Number of Vibrating Wire Sensors Measured | Up to 2 vibrating wire sensors can be connected to the analyzer module. Additional sensors can be measured by using an AM16/32-series multiplexer. |
Power Requirements | 9.6 to 16 Vdc |
Analog Input/Outputs | 2 differential (DF) vibrating wire measurements (V+ and V-) and 2 single-ended (SE) ratiometric resistive half-bridge measurements (T+ and T-) for vibrating wire sensor's onboard temperature sensor. |
Digital Control Ports |
3 digital control ports (C1 – C3)
|
RS-232 Port | 1 9-pin RS-232 port (for connecting to a data logger COM port) |
Measurement Resolution | 0.001 Hz RMS (±250 mV differential input range; -55° to +85°C) |
Measurement Accuracy | ±0.013% of reading (±250 mV differential input range; -55° to +85°C) |
Input Voltage Range | ±250 mV (differential) for vibrating wire inputs |
Common Mode Range | ±25 V |
Baud Rates | Selectable from 1200 to 38.4 kbps (ASCII protocol is one start bit, one stop bit, eight data bits, and no parity.) |
Memory |
|
CE Compliance Standards to which Conformity Is Declared | IEC61326:2002 |
Dimensions | 21.6 x 11.18 x 3.18 cm (8.5 x 4.5 x 1.2 in.) |
Weight | 0.43 kg (0.95 lb) |
Typical Current Drain @ 12 Vdc |
|
Quiescent, Radio Off | ~0.3 mA |
Radio Duty Cycling 1 s | ~3 mA (includes quiescent current) |
Radio Always On | ~26 mA (radio transmit current 100 mA) |
Active RS-232 Communication | ~6 mA (3 s after communication stops, the current will drop to the quiescent current.) |
Measurement | ~25 mA (averaged over the 2 s) |
Please note: The following shows notable compatibility information. It is not a comprehensive list of all compatible products.
Product | Compatible | Note |
---|---|---|
21X (retired) | ||
CR10 (retired) | The CR10 supports the SDI-12 mode only. | |
CR1000X (retired) | ||
CR1000Xe | ||
CR10X (retired) | The CR10X supports the SDI-12 mode only. | |
CR200X (retired) | ||
CR206X (retired) | ||
CR211X (retired) | ||
CR216X (retired) | ||
CR23X (retired) | The CR23X supports the SDI-12 mode only. | |
CR295X (retired) | ||
CR300 (retired) | ||
CR3000 (retired) | ||
CR310 | ||
CR350 | ||
CR500 (retired) | ||
CR5000 (retired) | The CR5000 supports the SDI-12 mode only. | |
CR510 (retired) | ||
CR800 (retired) | ||
CR850 (retired) | ||
CR9000 (retired) |
Product | Compatible | Note |
---|---|---|
ENC10/12 | If using the RS-232 port, the AVW206 must be mounted flat to fit in an ENC10/12. | |
ENC10/12R | If using the RS-232 port, the AVW206 must be mounted flat to fit in an ENC10/12Rl | |
ENC12/14 | If using the RS-232 port, the AVW206 must be mounted flat to fit in an ENC12/14. | |
ENC14/16 | ||
ENC16/18 | ||
ENC24/30 | ||
ENC24/30S |
The AVW206 Vibrating Wire Spectrum Analyzer Module allows our data loggers to measure vibrating wire strain gages, pressure transducers, piezometers, tiltmeters, crackmeters, and load cells.
The AVW206's internal spread spectrum radio can transmit data to an RF401A, RF401, or RF430. The AVW206 does not have a transparent mode, and therefore its internal radio cannot communicate with an RF400 radio.
The AVW206 requires a desiccated, non-condensing environment. A Campbell Scientific enclosure is recommended when the analyzer module is in the field. The AVW206 has built-in keyhole flanges for mounting to an enclosure backplate.
The AVW206 is typically powered by the data logger's power supply.
Newer modules with 250 mW radios must use OS 5 or higher for their operating system.
Example programs for the AVW200 and AVW206. The examples demonstrate a direct RS-232 connection to the AVW200, a wireless connection to an AVW206, an SDI-12 connection to the AVW200 and using multiplexers with the AVW200.
20749: 14