COM220电话用于支持PC与Campbell Scientific数据采集器之间通过固话网络进行通讯。PC端需要一个兼容Hayes标准的modem;COM220在远程站点接入数据采集器。与Campbell Scientific的大多数数据采集器相兼容。
COM220含有1个CS I/O端口,1个电源端子,1个接线端子,和1个RJ-11C插孔。数据采集器通过SC12 或 SC12R-6线缆连接到COM220的CS I/O端口。RJ-11C插孔用于连接带有浪涌保护的固话线。此外,接线端子(GND, RING, TIP)也可用于将COM220通过浪涌保护器连接到固话线。
Transmission Distance or Area | Worldwide |
Operation | 1200 to 115200 baud digital communications over phone lines |
Operating Voltage | 12 Vdc |
Current Drain |
|
Communication Rate | 9600, 38400, 57600, 115200 bps (between data logger and COM220, and selected by user) |
Operating Temperature Range | -25° to +50°C (standard) |
Standards | V.92, K56Flex, V.90, V.34, V.32bis, V32, V23, V22bis, V22, V.21, B212, B103 |
Registration |
|
Service Requirements | If not available at the site, phone lines must be installed. |
Dimensions | 16.5 x 2.5 x 6.6 cm (6.5 x 1.0 x 2.6 in.) |
Weight | 0.16 kg (0.35 lb) |
Please note: The following shows notable compatibility information. It is not a comprehensive list of all compatible products.
Product | Compatible | Note |
---|---|---|
21X (retired) | ||
CR10 (retired) | ||
CR1000X (retired) | ||
CR1000Xe | ||
CR10X (retired) | ||
CR200X (retired) | ||
CR206X (retired) | ||
CR211X (retired) | ||
CR216X (retired) | ||
CR23X (retired) | ||
CR295X (retired) | ||
CR300 (retired) | ||
CR3000 (retired) | ||
CR310 | ||
CR350 | ||
CR500 (retired) | ||
CR5000 (retired) | ||
CR510 (retired) | ||
CR6 | ||
CR800 (retired) | ||
CR850 (retired) | ||
CR9000 (retired) |
Typically, a length of phone line is run from the telephone company's junction box to the COM220s surge protector, and then to the Ground, Tip, and Ring terminals on the COM220. Alternately, if adequate surge protection is provided by the telephone company and the junction box supports it, a length of telephone wire with RJ11C connectors (pn 2365) can be run directly from the junction box to the socket on the COM220.
Default settings are not compatible for non-PakBus data loggers (i.e., CR5000, CR7, retired data loggers). For these data loggers, the DIP switch settings must be changed; refer to the COM220 manual for details.
An SC12 cable is provided for connecting the COM220 with the data logger.
LoggerNet and PC400 software packages support use of the COM220 with our data loggers. Both of these software packages support automated error-checking or user-initiated contacts. LoggerNet also supports scheduled contact times. Our software can run unattended allowing the user to take advantage of lower off-hour telephone rates.
The COM220 requires a desiccated, non-condensing environment; a Campbell Scientific enclosure is recommended. Grommets and screws are provided to attach the COM220 to the backplate of our enclosures.
Execution of this download installs the COM220 Operating System on your computer.
Note: The Device Configuration Utility is used to upload the included operating system to the COM220.
COM220: 14
展开全部收起全部
Cable runs of that length usually will require a booster of some sort. Contact the local phone company for recommendations.
Not directly. A data logger needs to be used with it, and the remote caller needs to be running LoggerNet or PC400.
Campbell Scientific does not recommend VoIP, as it does not work well with data transfers.
There are several possibilities as to the cause. Contact Campbell Scientific for assistance in determining the specific cause.
Typically, software such as LoggerNet or PC400 is needed to connect to a data logger and download the data.
Refer to the “Installation” section of the COM220 Telephone Modem Instruction Manual.
All data loggers will work with the COM220 except the CR200X-series dataloggers.